beautypg.com

Operation, Winterwarm small insert, Your winterwarm insert’s controls and what they do – Vermont Casting 2080 User Manual

Page 9: Primary air control, The damper

background image

9

WinterWarm Small Insert

2000888

Operation

Your WinterWarm Insert’s

Controls and What They Do

All WinterWarm Small Insert controls are conveniently
located on the front. (Fig. 8)
Three controls regulate the performance of your Winter-
Warm Small Insert:
The primary air control supplies oxygen for the fire.
The damper directs air flow within the fireplace.
The variable-speed fan control, or rheostat, regulates
the warm air flow into the room.

FP1099

WWsi

controls

4/01

Damper Control

Lever

Primary Air

Control Lever

Fan Speed Control

FP1099

Fig. 8 WinterWarm Small Insert controls.

Primary Air Control

A single air control regulates the amount of heat the fire
will produce and how long it will burn.
The primary air control lever is located midway up
the left side panel. The lever regulates air for starting,
maintaining, and reviving the fire.
Generally, more air entering the stove makes the fire
burn hotter and faster, while less air prolongs the burn.
The WinterWarm Small Insert’s air supply is increased
when the control lever is moved counterclockwise, and
decreased when moved clockwise. It may be set any-
where between the two extremes, however, depending
on the amount of heat desired. (Fig. 9)
To complement the manual setting of the air control,
the WinterWarm Small Insert has an internal automatic
thermostat that ensures an even delivery of heat at the
manual setting you select.

2:00 High

3:00 Medium

4:00

4:30 Low

FP1100

WWsi

air control settings

4/03/01 djt

Primary Air Control Lever

FP1100

Fig. 9 Settings for the primary air control range from 2:00
(high burn rate) to 4:30 (low burn rate).

The Damper

The damper directs air flow within the fireplace. The
damper is operated by moving the lever located above
the door. It has two positions: Open, to start or revive
the fire; and closed, for normal operation. The damper
is open when the lever is to the far right, and closed
when to the far left. There are no intermediate settings
for damper position. (Fig. 12)
To open the damper, insert the fall-away handle into the
hole in the lever, lift up on the lever and move it to the
far right.
To close the damper, move the lever to the left, continu-
ing past the resistance to lock the damper in position.

FP1072a

WWsi

damper closed

4/3/01

FP1071a

WW si

damper open

4/03/01 djt

Damper

Secondary Air

Inlet

Damper

Catalytic

Combustor

Secondary Air

Inlet

FP1071/2a

Damper Open

Damper Closed

Fig. 10 When the damper is open, smoke is vented directly
to the chimney. When the damper is closed, smoke is chan-
nelled through the catalytic combustor.