TECHNICAL DATA

DIMENSIONS

Height

900 - 915 mm

Widht

1000 mm

Depth

600 mm (excluding door handles)

GENERAL

Gas connection

Rp ½ (½" BSP female)

Pressure test point

Hotplate burner injector

Gas rate adjustment

None

Aeration adjustment

None

Electrical connection

230-240V~ 50Hz.

Total electrical heat input

6.00-6.80 kW

INSTALLATION INSTRUCTIONS

230-240V~

Cat II2H3+

G20 at 20 mbar

Cat II2H3+

G30 at 28 - 30 mbar

G31 at 37 mbar

BURNER

HEAT INPUT

HEAT INPUT

INJECTOR

HEAT INPUT

GAS RATE

INJECTOR

BY-PASS

HOTPLATE

Front Left

1.90 kW

102 Z

1.90 kW

138 g/hr

64

35

HOTPLATE

Rear Left

3.00 kW

116 Y

3.00 kW

218 g/hr

86

44

HOTPLATE

Wok Inner

Centre Front

4.10 kW

110 x 24.10 kW

298 g/hr

70 x 257

HOTPLATE

Wok Outer

Centre Front

1.00 kW

74

1.00 kW

73 g/hr

44

24

HOTPLATE

Auxiliary

Centre Rear

1.00 kW

71 X

1.00 kW

73 g/hr

50

24

HOTPLATE

Front Right

1.50 kW

88 X

1.50 kW

110 g/hr

60

35

HOTPLATE

Rear Right

1.50 kW

88 X

1.50 kW

110 g/hr

60

35

TWIN GRILL

2.50 kW

L/H OVEN

1.60 kW

R/H OVEN

1.80 kW

WARMING

DRAWER

0.10 kW