TECHNICAL DATA
DIMENSIONS
Height
900 - 915 mm
Widht
1000 mm
Depth
600 mm (excluding door handles)
GENERAL
Gas connection
Rp ½ (½" BSP female)
Pressure test point
Hotplate burner injector
Gas rate adjustment
None
Aeration adjustment
None
Electrical connection
230-240V~ 50Hz.
Total electrical heat input
6.00-6.80 kW
INSTALLATION INSTRUCTIONS
230-240V~
Cat II2H3+
G20 at 20 mbar
Cat II2H3+
G30 at 28 - 30 mbar
G31 at 37 mbar
BURNER
HEAT INPUT
HEAT INPUT
INJECTOR
HEAT INPUT
GAS RATE
INJECTOR
BY-PASS
HOTPLATE
Front Left
1.90 kW
102 Z
1.90 kW
138 g/hr
64
35
HOTPLATE
Rear Left
3.00 kW
116 Y
3.00 kW
218 g/hr
86
44
HOTPLATE
Wok Inner
Centre Front
4.10 kW
110 x 24.10 kW
298 g/hr
70 x 257
HOTPLATE
Wok Outer
Centre Front
1.00 kW
74
1.00 kW
73 g/hr
44
24
HOTPLATE
Auxiliary
Centre Rear
1.00 kW
71 X
1.00 kW
73 g/hr
50
24
HOTPLATE
Front Right
1.50 kW
88 X
1.50 kW
110 g/hr
60
35
HOTPLATE
Rear Right
1.50 kW
88 X
1.50 kW
110 g/hr
60
35
TWIN GRILL
2.50 kW
L/H OVEN
1.60 kW
R/H OVEN
1.80 kW
WARMING
DRAWER
0.10 kW