beautypg.com

Ppendix, General troubleshooting – Chauvet Laser Level User Manual

Page 13

background image

MinLaser User Manual

13

August 2011

5.

A

PPENDIX

General Troubleshooting

S

YMPTOM

P

OSSIBLE

C

AUSE

(

S

)

P

OSSIBLE

A

CTION

(

S

)

Breaker/Fuse

keeps blowing

 Excessive circuit load

 Check total load placed on the

electrical circuit.

 Short circuit along the

power wires

 Check for a short in the electrical

wiring (internal and/or external).

Device does not

power up

 No power

 Check for power on Mains.

 Loose power cord

 Check power cord

Fixture is not

responding to

DMX

 Wrong DMX addressing

 Check Control Panel and unit

addressing

 Damaged DMX cables

 Check DMX cables

 Wrong polarity settings on

the controller

 Check polarity switch settings on

the controller

 Loose DMX cables

 Check cable connections

 Faulty DMX interface

 Replace DMX input

 Faulty Main PCB

 Replace Main PCB

Loss of signal

 Non DMX cables

 Use only DMX compatible cables

 Bouncing signals

 Install terminator as suggested.

 Long cable / Low level

signal

 Install amplifier right after fixture

with strong signal.

 Too many fixtures

 Install an optically coupled DMX

splitter after unit #32.

 Interference from AC wires  Keep DMX cables separated from

power cables or black lights.





If you still have a problem after trying the above solutions, please contact CHAUVET®