Comes Close to a Cobra

®

Mounting And

Powering The Radio

19

18 English

Warning Sticker

FCC regulations require that the Warning Sticker

supplied with this radio be applied to a spot where

it is easily seen by the radio operator. Be sure the

location is clean and dry before applying the sticker.

Electrical Power Connection

Your CobraMarine VHF radio is powered

from the vessel’s 13.8-volt negative

ground direct current electrical system

(12-volt nominal). A fused power

connection lead is provided at the back

of the transceiver.
To Connect To A Power Source:
1.
Attach the black (-) wire to a

negative (-) ground.

2. Attach the fused red power (+) wire

to the positive (+) side of the power

system.

NOTE

This radio will draw up to 8 amps when transmitting at full power.

NOTICES

A reverse polarity connection will damage the radio.
When replacing the fuse in your transceiver, use only the size and type

originally provided.

Installation And Start-Up

Installation And Start-Up

Mounting And

Powering The Radio

Warning Sticker

Power Connection Cables

Red Cable

Positive (+)
Black Cable

Negative (-)

– +

NOTE

All wiring is best kept as short as possible. If the power leads must be

extended, use a high-quality, marine-grade cable sized for up to 10 amps

of current. To minimize voltage drop, choose a wire gauge as follows:

Length

Wire Gauge

Up to 1.5m(4.9ft)

1.6 mils(#14)

Up to 3.0m(9.8 ft)

2.0 mils(#12)

Up to 5.0m(16.4 ft)

2.6 mils(#10)

Up to 6.0m(19.7 ft)

3.3 mils(#8)