Installation, Technical specification inverter arc™ 120 – Century INVERTER ARC IM998 User Manual
Page 10

A-1
INSTALLATION
INVERTER ARC™ 120
A-1
Input Circuit
120 Vac
Maximum Open Circuit Voltage
72 Volts Max.
Duty Cycle
20%
Output Current Range
10-90 Amps
INPUT - SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT
Height
Width
Length
Weight
7.5 in.
5.0 in.
10.9 in.
Approx. 14.0 lbs.
190.5 mm
127.0 mm
276.9 mm
6.4 kgs.
PHYSICAL DIMENSIONS
TEMPERATURE RANGES
OPERATING TEMPERATURE RANGE
-10°C to +40°C
STORAGE TEMPERATURE RANGE
-25°C to +55°C
RECOMMENDED INPUT WIRE AND FUSE SIZES FOR MAXIMUM RATED OUTPUT
INPUT VOLTAGE /
FREQUENCY (HZ)
120/60
MAXIMUM TIME-DELAY CIRCUIT
BREAKER OR FUSE SIZE (AMPS)
20
TYPE SJT OR HARD USAGE INPUT
CORD
3 Conductor, 14 AWG
Input Voltages 60 Hz.
120Vac ± 15%
Rated Input Current
20 Amps @ Rated Output
Output Amps
70A (Stick)
Output Volts
22.8 Vdc
Type of Output
DC
TECHNICAL SPECIFICATION INVERTER ARC™ 120