Safety, Trouble shooting – Cecilware EL-1624 User Manual
Page 5
4
Safety
*A Cecilware Recommended Qualified Service Technician should carry out repairs if necessary. Do not
remove any components or service panels on this product.
*Allow the Griddle to cool down after use before dismantling for cleaning; the unit will be too hot to handle
immediately after use.
*When cleaning, switch off power and disconnect from the outlet.
*Do not immerse unit in water or use hose to clean.
*If the power cord is damaged, it must be replaced by a Cecilware Recommended Qualified Service
Technician in order to avoid a hazard.
Trouble Shooting
If the Cecilware Griddle does not operate, please check the following before placing a service call.
Top Griddle
El-1624, EL-1636
Problem
Cause
Remedy
1. Mains power supply
1. Check mains power supply
2. Power switch has not been
turned on
2. Check the unit is correctly plugged in and
turned on
3. Fuse in the plug has blown
3. Replace the fuse in the plug with correctly
rated fuse
4. Plug and lead are damaged
4. Call service agent or qualified technician
5. Internal wiring fault
5. Call service agent or qualified technician
The unit is not working
and the indicator light is
not on
6. Thermal cut-out has activated
6. This is a safety device that has
disconnected the power: call a service
agent or qualified technician
The unit is heating but the
indicator light is not on
1. The indicator bulb has blown
1. Replace the indicator light: call a service
agent or qualified technician