Safety


*A Cecilware Recommended Qualified Service Technician should carry out repairs if necessary. Do not
remove any components or service panels on this product.

*Allow the Griddle to cool down after use before dismantling for cleaning; the unit will be too hot to handle
immediately after use.

*When cleaning, switch off power and disconnect from the outlet.

*Do not immerse unit in water or use hose to clean.

*If the power cord is damaged, it must be replaced by a Cecilware Recommended Qualified Service
Technician in order to avoid a hazard.

Trouble Shooting

If the Cecilware Griddle does not operate, please check the following before placing a service call.

Top Griddle

El-1624, EL-1636

Problem

Cause

Remedy

1. Mains power supply

1. Check mains power supply

2. Power switch has not been

turned on

2. Check the unit is correctly plugged in and

turned on

3. Fuse in the plug has blown

3. Replace the fuse in the plug with correctly

rated fuse

4. Plug and lead are damaged

4. Call service agent or qualified technician

5. Internal wiring fault

5. Call service agent or qualified technician

The unit is not working

and the indicator light is

not on

6. Thermal cut-out has activated

6. This is a safety device that has

disconnected the power: call a service

agent or qualified technician

The unit is heating but the

indicator light is not on

1. The indicator bulb has blown

1. Replace the indicator light: call a service

agent or qualified technician