beautypg.com

Desa Tech CGP11 User Manual

Page 13

background image

13

4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the

floor. If you then smell gas, STOP! Follow “B” in the safety information at the
top of page 12. If you don’t smell gas, go to the next step.

5. Press in control knob.

Note:

You may be running this heater for the first time after hooking up to gas

supply. If so, the control knob may need to be pressed in for 30 seconds. This
will allow air to bleed from the gas system.

• If control knob does not pop up when released, contact a qualified service

person or gas supplier for repairs.

6. Keep control knob pressed in and turn it counterclockwise

C-clockwise

to the

PILOT/IGN position. This will light pilot.

Note:

You will hear a loud “click” when the control knob reaches the

PILOT/IGN position.

If pilot does not light

• turn control knob clockwise

Clockwise

to the OFF position

• repeat steps 5 and 6

If pilot does not stay lit after several tries

• refer to TROUBLESHOOTING, pages 17 through 20
• contact a qualified service person or gas supplier

Until repairs are made, light pilot with match. To light pilot with match, see

MANUAL LIGHTING PROCEDURE, page 15.

7. Keep control knob pressed in for 10 seconds after lighting pilot. After 10 sec-

onds, release control knob.

Note:

If pilot goes out, repeat steps 3 through 7.

Ignitor Electrode

Figure 15 - Pilot

Pilot Burner

Thermocouple