beautypg.com

Campbell Hausfeld 4-Channel Current/Voltage SDM-CVO4 User Manual

Page 25

background image

Instruction Manual

; Wait 100 m

it to power-on an

s for

d the outputs to stabilize

; You ma

increase this dela

y need to

y if the sensors ; themselves

; have a power-on delay

3: Excitation with Delay (P22)
1: 1

Ex

Channel

2: 0000

Delay W/Ex (units = 0.01 sec)

3: 10

Delay After Ex (units = 0.01 sec)

4: 0000

mV

Excitation


; Take the four

easurements from

m

sors.

the Pressure sen


4: Volt (Diff) (P2)
1: 4

Reps

2: 04

250 mV Slow Range

3: 1

DIFF

Channel

4: 5

Loc [ Press_1 ]

5: 1.0

Mult

6: 0.0

Offset


; Now turn o

SDM-CV

ff the

O4 by using the command with 0 reps.


5: SDM-AO4 (P103)
1: 0

Reps

2: 00

SDM

Address

3: 1

Loc [ Scale_1 ]


; Now the normal output processing and final storage
; i

ns wou

mple:

nstructio

ld follow, for exa


; Every hour set the output flag

6: If time is (P92)
1: 0

Minutes (Seconds --) into a

2: 60

Interval (same units as above)

3: 10

Set Output Flag High (Flag 0

)


; Store time

7: Real Time (P77)
1: 1110

Year,Day,Hour/Minute (midnight = 0000)


; Store the average readings

8: Average (P71)
1: 4

Reps

2: 5

Loc [ Press_1 ]

19