Installation Instructions

Figure a

Figure b

Figure c

Figure e

Figure f

Figure g

Figure d

+5°

-5°

Escalones de

nivelación de

fundición

(5°)

+5°

Escalones de nivelación de fundición

(Grados de ajuste)

5° 2½° 0° (2½°) (5°)

Pernos delsoporte

de montaje

Traba con resorte para

abrir sin herramientas

Brazo

Soportes de

montaje

Updated 5/20/2014

Carcasa de la fuente de

alimentación

DESDE LA LUZ

(CON TENSIÓN,

SALIENTE)

BORNERA

TIERRA

TIERRA

NEMA

DESCAR-

GADOR DE

SOBRETEN-

SIONES

TIERRA

DESDE EL POSTE (C

ON TENSIÓN, ENTR

ANTE)

Inspection

The packaging has been designed to protect the luminaire from damage during transit. Inspect luminaire

for damage before installation.

Handling

Never lift or handle the luminaire by holding the power supply housing. Instead, the luminaire should be

lifted by grasping both the LED deck and the rear luminaire housing (see figure f).

Mounting the Luminaire on a Round Tenon Arm

To mount the luminaire, begin by opening the wiring compartment door using the tool-less, spring-

loaded latch (see figure a).

The luminaire mounts to round tenon arms with 1.625” to 2.375” outside diameters.

Loosen (do not remove) the fitter bolts.

Lift the luminaire into position in front of the tenon arm such that the tenon arm enters through

theopening at the rear of the luminaire and between the fitter bracket and the luminaire housing.

Insert the tenon arm through the fitter brackets and onto the cast leveling steps as far as required to

properly level the luminaire. Each steps equals 21⁄2 degrees of luminaire tilt.

If more upward tilt of the front of the luminaire is needed, lift the front of the luminaire and move it back

until the tenon rests on the next set of leveling steps toward the front of the luminaire. This will provide

21⁄2 degrees of upward tilt. If an additional 21⁄2 degrees of upward tilt is required, move the luminaire

back to the next set of leveling steps (see figure e & f).

If downward tilt is needed, reverse the procedure by lifting the back of the luminaire, and sliding the

luminaire forward onto either of the other leveling steps toward the rear of the luminaire.

With the luminaire properly positioned, initially tighten the mounting clamp bolts to approximately 6-8

foot pounds. Use an alternating pattern of bolt tightening to ensure secure seating of the mounting

brackets onto the tenon.

Check the luminaire position for the correct degree of front-to-back tilt, and to make sure the side- to-

side position of the luminaire is level. After final adjustments are made, tighten the mounting clamp

bolts to 14-16 foot pounds again using an alternating pattern of bolt tightening. The torqued bolts and

mounting clamps should provide a firm grip on the tenon and prevent any movement or rotation. Do not

over-tighten the mounting bracket bolts.

Wiring

NOTE: Make sure that all electrical connections are in accordance with the National Electrical Code

(NEC) and any applicable local code requirements.

NOTE: Check the rated input voltage on the luminaire product label, and verify that the supply voltage

meets the product requirements.

Wiring connections are made on the terminal block inside the wiring compartment (see figure c).

Wire leads to terminal block according to the wiring diagram (see figure g). Connect wire leads as

follows:

o CONNECT WHITE (common) supply wire to white luminaire wire.

o CONNECT BLACK (hot) supply wire to black luminaire wire.
o CONNECT GREEN (ground) supply wire to green luminaire wire.

When making electrical connections, make sure that the ground wire on the supply side is connected to

the ground lug on the terminal block. Under no circumstances should the ground wire be connected to

a supply or power wire. This will cause the luminaire to fail, and the luminaire will not be covered under

warranty.

After all connections have been made, close the wiring compartment door, and make sure it is securely

latched.

Test luminaire by installing a shorting cap or photocell in the photocell receptacle.

Maintenance

Depending on environmental conditions, it may be necessary to clean the lens in order to maintain a

high-efficiency lens. (Use solvent-free cleaners.)

Storage

Prior to installation, the luminaire should be placed in a covered, dry storage. The storage location

should not exceed the normal operating temperature of the luminaire.

Green Star Products Inc. • greenstarled.com • 6900 Alamo Downs Pkwy. Ste 120 • San Antonio, TX 78238 • 210-370-9640 • [email protected]