Setup
Removal
NOTE: To prevent damage to multi-pin connector and wiring, use care 
when handling the TPMC-4XG-BTP. 
Perform the following procedure to remove the existing 
TPMC-4XG-BTP from a TPMC-4XG or TPMC-4XG-B touchpanel: 
1. Place the touchpanel screen side down on a clean, soft surface. 
2. Remove the battery compartment cover on the rear of the 
touchpanel.
3. Using the flat end of a small slot head screwdriver, gently pry the
multi-pin connector off the corresponding connector in the battery 
compartment of the touchpanel. 
4. With the multi-pin connector detached from the touchpanel, lift the
TPMC-4XG-BTP out of the battery compartment.
Installation
After completing removal of the old TPS-4XG-BTP from the touchpanel 
(refer to “Removal” above), perform the following procedure to install 
the TPMC-4XG-BTP in a TPMC-4XG or TPMC-4XG-B touchpanel: 
1. Place the TPMC-4XG-BTP in the battery compartment oriented so
the multi-pin connector is on the top.
2. Carefully connect the multi-pin connector of the TPMC-4XG-BTP
with the corresponding connector inside the battery compartment. 
The pin side of the connector should be facing downward (toward 
the front of the touchpanel). 
NOTE: When installing the battery in the touchpanel, ensure the 
connecting wires are not under the battery. Refer to the photo on the 
following page for proper wire routing. 
3. Re-attach the battery compartment cover.
Installation Guide – DOC. 6657B
Internal Battery Pack: TPMC-4XG-BTP
• 3