Factory default unit settings, Factory default configuration settings, Factory default patch parameters – Compex Systems AP4530 User Manual
Page 46

46
IDR-8 User Guide
Factory default unit settings
Unit name – iDR Unit Name 
Network settings 
 DHCP 
–
No
IP address – 192.168.0.1
Net mask – 255.255.255.0
PPP settings 
 
Host IP address – 192.168.0.1
Client IP address – 192.168.0.2
User name – iDR
Password
–
A&H
Factory default configuration settings
Input channel names 
 
I/P 1…. I/P 16
Output channel names 
 
O/P 1…. O/P 16
Input group names 
 
IP Grp 1…. IP Grp 8
Output group names 
 
OP Grp 1…. OP Grp 8
Stereo selections 
 All 
mono
Communications option 
 
A RS232 B SysNet
Scheduled events 
 None 
Power-up patch 
 None 
All patches empty 
Factory default patch parameters
AMM 
 No 
active
inputs
No active outputs
Threshold
7dB
Gate depth 40dB
Hold time 1s
NOM
attenuation
3dB
Input delays 
 All 
0ms
Output delays 
 All 
0ms
Input faders, mutes, groups 
 
Fader levels off
Mutes
off
Group
assignments
none
Group
levels
0dB
Input patchbay 
 
XLR 1 to Channel 1….
XLR 8 to Channel 8
Expander 9 to Channel 9….
Expander 16 to Channel 16
 
 
Output patchbay 
Channel 1 to XLR 1….
Channel 8 to XLR 8
Expander 9 to XLR 9….
Expander 16 to XLR 16
LCD 
 
Line 1 – user text ‘Allen & Heath’
Line
2
–
time
Mic preamps 
 Pad 
on
Gain +20dB (resulting gain 0dB)
+48V
off
Limiter
off
Monitor manager 
 
Follow mouse / active window
Routing matrix 
 
All cross points 0dB (on)
Signal generator 
 
Signal type – sine wave
Frequency
–
440Hz
Level - -30dB
Front panel soft keys 
 
S1-S8 – input level control CH1-8
S9-S16 – output level control CH1-8
iDR-switch inputs 
 S1-S24 
–
unused
Front panel soft LEDs 
 
L1-L16 – static LED off
L17-L24 – input source meters CH1-8
L25-L32 – output post limiter meters CH1-8
iDR-switch outputs 
 
S1-S16 – static LED off
Input expander 
 
S1-S8 – input source meters CH9-16
Output expander 
 
S1-S8 – Output post limiter meters CH9-16