Reference

Low Battery Alarm

If the transmitter battery voltage drops to 4.2V or less, an audible alarm will sound
and "LOW v" will be displayed on the LCD screen.

LCD screen:

Backup Error

If the data is lost for an unknown reason, an audible alarm will sound and "ERR" will be
displayed on the LCD screen.

LCD screen:

RF Error

If the RF circuit is failed for an unknown reason, an audible alarm will sound and "RF"
will be displayed on the LCD screen. Please request repair from the Futaba Service
Center

LCD screen:

Error Displays

nWARNING

When a low batter y alarm is generated, cease operation
immediately and retrieve the model. If the battery goes dead
while in operation, you will lose control.

nWARNING

When a backup error is generated, immediately stop using the
system and request repair from the Futaba Service Center. If
you continue to use the system, the transmitter may malfunction
and cause loss of control.