Physical data, Vapor line sizing and cooling capacity loss, 25h c d 3 – FloAire 25HCD3 User Manual
Page 3

3
PHYSICAL DATA
UNIT SIZE SERIES
18---30
24---30
30---30, 50
36---31, 50,
60
42---31, 50
48---31, 50,
60
60---30, 50, 60
Operating Weight lb (kg)
119
(54.1)
124
(56.4)
149
(67.7)
169
(76.7)
180
(81.6)
208
(94.3)
250
(113.4)
Shipping Weight lb (kg)
137
(62.3)
142
(64.5)
170
(77.3)
189
(85.9)
200
(90.9)
228
(103.6)
282
(127.9)
Compressor Type
Scroll
REFRIGERANT
Puron (R---410A)
Indoor Control
Piston
49
Piston
57
Piston
67
Piston
70 (31)
73 (50,60)
Piston
76
Piston
80 (31)
82 (50, 60)
TXV
(Puron Hard
Shutoff)
Outdoor Heating Piston #
42
49
55
57
63
65
76
Charge lb (kg)
4.0
(1.81)
5.11
(2.32)
5.83
(2.64)
6.06
(2.75)
6.75
(3.06)
7.72
(3.50)
11.00
(4.99)
COND FAN
Propeller Type, Direct Drive
Air Discharge
Vertical
Air Qty (CFM)
1800
2100
3000
3000
3400
3400
4000
Motor HP
1/12
1/10
1/5
1/5
1/4
1/4
1/4
Motor RPM
1100
1100
1100
1100
1100
1100
800
COND COIL
Face Area (Sq ft)
9.8
11.2
15.0
17.2
17.2
15.0
17.6
Fins per In.
20
20
20
20
20
20
20
Rows
1
1
1
1
1
2
2
Circuits
3
4
5
5
5
6
8
VALVE CONNECT. (In.) ID
Vapor
5/8
5/8
3/4
3/4
7/8
7/8
7/8
Liquid
3/8
REFRIGERANT TUBES* (In.) OD
Rated Vapor*
5/8
5/8
3/4
3/4
7/8
7/8
1---1/8
Liquid
3/8”
*Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset.
Note
: See unit Installation Instruction for proper installation.
VAPOR LINE SIZING AND COOLING CAPACITY LOSS
Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line
diameters shown in the chart below are acceptable for HP systems with Puron refrigerant:
Vapor Line Sizing and Cooling Capacity Losses -- Puronr Refrigerant 1-- Stage Heat Pump Applications
Unit
Nominal
Size (Btuh)
Maximum
Liquid Line
Diameters
(In. OD)
Vapor Line
Diameters
(In.) OD
Cooling Capacity Loss (%)
Total Equivalent Line Length ft. (m)
Standard
Application
Long Line Application Requires Accessories
26---50
(7.9---15.2)
51---80
(15.5---24.4)
81---100
(24.7---30.5)
101---125
(30.8---38.1)
126---150
(38.4---45.7)
151---175
(46.0---50.3)
176---200
(53.6---60.0)
201---225
(61.3---68.6)
226---250
(68.9---76.2)
18,000
1---Stage
HP with
Puron
3/8
1/2
1
2
3
4
6
7
8
9
10
5/8
0
0
1
1
1
2
2
3
3
24,000
1---Stage
HP with
Puron
3/8
5/8
0
1
1
2
3
3
4
4
5
3/4
0
0
0
0
1
1
1
1
1
30,000
1---Stage
HP with
Puron
3/8
5/8
1
2
3
3
4
5
6
7
8
3/4
0
0
1
1
1
2
2
2
3
7/8
0
0
0
0
1
1
1
1
1
36,000
1---Stage
HP with
Puron
3/8
5/8
1
2
4
5
6
7
9
10
11
3/4
0
0
1
1
2
2
3
3
4
7/8
0
0
0
0
1
1
1
1
2
42,000
1---Stage
HP with
Puron
3/8
3/4
0
1
2
2
3
4
4
5
6
7/8
0
0
1
1
1
2
2
2
3
48,000
1---Stage
HP with
Puron
3/8
3/4
0
1
2
3
4
5
5
6
7
7/8
0
0
1
1
2
2
2
3
3
60,000
1---Stage
HP with
Puron
3/8
3/4
1
2
4
5
6
7
9
10
11
7/8
0
1
2
2
3
4
4
5
5
1---1/8
0
0
0
1
1
1
1
1
1
Standard Length = 80 ft. (24.4 m) or less total equivalent length
Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines
Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit See Long Line Applica-
tion Guidelines
25H
C
D
3