The Polyester junction box is designed for the parallel connection of up to 6, 8 or 10 load cells.
Type
No. of load cells
Housing size
Inputs
Output
Designation
KPEX-6
up to 6
160 x 260 x 90 mm
6x M16
KPEX-8
up to 8
8x M16
KPEX-10
up to 10
160 x 360 x 90 mm
10x M16
1x M20
EEx ia IIC T6
The junction box type KPEX can be connected to the instrumentation with a shielded 6-wire signal cable.
Corner correction is not prepared.
Housing material:
Polyester
Protection class:
IP66
Cable connection:
With screw terminals
Corner correction:
Not prepared
M
ECHANICAL
I
NSTALLATION
Look for a mounting location which is more or less dry and protected from environmental stress.
L
OAD
C
ELL
C
ABLE
C
ONNECTION
First the cable gland must be loosened. Then you have to feed the load cell cable through the cable gland
unless the shrink tube is fully disappeared in the box. The wires have to run below the printed circuit board
and will be pulled back to the top at the upper end of the printed circuit board. Afterwards you can connect the
cables to the screw terminals as indicated below.
For KPEX-6
Terminal no.
Cable coulour
Description
LC1
LC2
LC3
LC4
LC5
LC6
yellow
= Cable shield
1
2
3
28
29
30
red
= –Output / Signal –
22
23
24
25
26
27
white
= +Output / Signal +
10
11
12
13
14
15
black
= –Input / Excitation –
(if appl., brown)*
= Sense –
16
17
18
19
20
21
green
= +Input / Excitation +
(if appl., blue)*
= Sense +
4
5
6
7
8
9
For KPEX-8
Terminal no.
Cable coulour
Description
LC1
LC2
LC3
LC4
LC5
LC6
LC7
LC8
yellow
= Cable shield
1
2
3
4
37
38
39
40
red
= –Output / Signal –
29
30
31
32
33
34
35
36
white
= +Output / Signal +
13
14
15
16
17
18
19
20
black
= –Input / Excitation –
(if appl., brown)*
= Sense –
21
22
23
24
25
26
27
28
green
= +Input / Excitation +
(if appl., blue)*
= Sense +
5
6
7
8
9
10
11
12
For KPEX-10
Terminal no.
Cable coulour
Description
LC1
LC2
LC3
LC4
LC5
LC6
LC7
LC8
LC9
LC10
yellow
= Cable shield
1
2
3
4
5
46
47
48
49
50
red
= –Output / Signal –
36
37
38
39
40
41
42
43
44
45
white
= +Output / Signal +
16
17
18
19
20
21
22
23
24
25
black
= –Input / Excitation –
(if appl., brown)*
= Sense –
26
27
28
29
30
31
32
33
34
35
green
= +Input / Excitation +
(if appl., blue)*
= Sense +
6
7
8
9
10
11
12
13
14
15
* if load cell is equiped with 6-wire conductor cable