6. TECHNICAL SPECIFICATIONS
FVC 2001-EK
FVC 2003-EK
Voltage/Frequency
230 V ~ 50 HZ
230 V ~ 50 HZ
Power input
250 W
400 W
Maximum transferred amount
5000 l/h
7500 l/h
Maximum delivery
6 m
5 m
Maximum submersible depth
5 m
5 m
Maximum temperature of the media
35 °C
35 °C
Maximum value of solid particles in the media
Dia. 5 mm
Dia. 35 mm
Height of the switching point: On
Approx. 50 cm
Approx. 50 cm
Height of the switching point: Turned off
Approx. 5 cm
Approx. 5 cm
7. WHAT TO DO "WHEN..."
When...
Causes
Repairs
The pump does not start
– No power supply
– The fl oat does not switch
– Check the power supply
– Move the fl oat to a higher position
Not fl owing
– The suction sieve is clogged
– The pressure hose is bent
– Flush out the suction sieve with
a current of water
– Straighten the hose
The pump does not
turn off
– The fl oat cannot fall lower
– Place the pump correctly
on the fl oor of the tank
Insuffi cient fl ow
– The suction sieve is clogged
– Lowered pump capacity due to dirty
and silted water
– Clean the suction sieve
– Clean the pump and fl ush the hose
with clean water
The pump turns off
after a short time
– The temperature fuse stops the
pump due to dirty water
– The water is too hot. The temperature
fuse stops the pump
– Disconnect the power plug.
Clean the pump and the pumping pit
– Check that the maximum water
temperature of 35 °C is not exceeded
Note: Not covered by warranty:
Damage to the rotating mechanical gasket caused by running the pump empty, or by foreign objects
in the water
Blocking of the running wheel by foreign objects
Damage during transport
Damage caused by unprofessional alterations by persons