beautypg.com

Cecilware GB1P User Manual

Page 8

background image

TROUBLESHOOTING GUIDE FOR GB-POUROVER

WARNING: To reduce the risk of electrical shock unplug the dispenser power cord before repairing or replacing
any internal components of the unit.. Before any attempt to replace a component be sure to check all electrical

connections for proper contact.
PROBLEM

PROBABLE

CAUSE

REMEDY

A Dispensing unit unplugged

Reconnect dispensing unit

B No power from Terminal Block

Check the Terminal Block for loose wire

C Defective Bulb

Replace Bulb.

D Defective Ballast.

Replace Ballast.

1

Light Display

not lit.

No power.

E Loose Bulb in socket.

Make sure bulb is seated properly in socket.

A Water supply OFF.

Turn water ON.

B Clogged inlet screen (Water Inlet Valve). Disconnect water line and clean inlet screen.
C Inoperative Water Inlet Valve.

Check connection, if needed replace Valve.

2

No water

when Rinse

Switch is ON. D Loose electrical connection.

Check all electrical connections.

A No product in Hopper.

Add product.

B Auger not working.

Engage Hopper/Nut to Motor Gear (See section VI).

C Damaged, loose, or missing Agitator

Gear.

Replace Agitator/Auger Gear (See section VI).

D Inoperative Auger Motor or Relay.

Check connections of Motor, Relay and/or Switch,
if needed replace components.

E Hopper outlet clogged

Clean Hopper and check Cartridge Heater.

3

No product

when

Dispense

Button is

pressed

F Faulty Coupling.

Replace damaged Coupling components.

A Leaking Water Inlet Valve.

Clean/check fittings of Water Inlet Valve. Replace

Water Inlet Valve if needed. See ”Water Inlet Valve
Test”

B Inoperative Dispense Switch

Check Switch connections.

Replace Dispense Switch if needed.

C Inoperative Rinse Switch

Check Rinse Switch connections.
Replace Rinse Switch if inoperative.

4

Water does

not shut off.

Water keeps

dispensing.

D Clogged/stuck Water Dispense Valve

Clean or unclog Water Dispense Valve.
Replace Dispense Valve if inoperative.

A Heater Switch is OFF.

Turn Heater Switch ON.

B Thermostat is OFF.

Turn Thermostat ON. Turn Knob Clockwise.

C Loose connection on Thermostat.

Make sure all wires and terminals on Thermostat are
tight.

D Hi-Limit Temperature Switch is defective Replace the Hi-limit.

5

Water is not

heating up in

the HOT

water tank.

E Heater is burned out or defective.

Replace the Heater.



8

This manual is related to the following products: