Protect the extension cords from sharp
8.
objects, excessive heat, and damp or
wet areas.
recOMMended MiniMuM wire
gauge FOr extenSiOn cOrdS*
(120/240 VOlt)
naMeplate
aMpereS
(at full load)
extenSiOn cOrd
length
25’
50’
75’
100’
150’
0 – 2.0
18
18
18
18
16
2.1 – 3.4
18
18
18
16
14
3.5 – 5.0
18
18
16
14
12
5.1 – 7.0
18
16
14
12
12
7.1 – 12.0
18
14
12
10
-
12.1 – 16.0
14
12
10
-
-
16.1 – 20.0
12
10
-
-
-
taBle a
* Based on limiting the line
voltage drop to five volts at
150% of the rated amperes.