3.2 Nominal data
Motor
M6E110-IA
Phase
3~
Nominal voltage / VAC
230
Frequency / Hz
50
Type of data definition
ml
Valid for approval /
standard
CE
Speed / min
-1
900
Power input / W
630
Current draw / A
2.79
Motor capacitor / µF
14
Capacitor voltage / VDB
450
Max. back pressure / Pa
105
Min. ambient temperature
/ °C
-40
Max. ambient
temperature
/ °C
65
Starting current / A
6.9
Maximum safe operating
speed / min
-1
1140
@ 70 °C
ml = Max. load · me = Max. efficiency · fa = Running at free air
cs = Customer specs · cu = Customer unit
Subject to alterations
3.3 Data according to ErP directive
Installation category
A
Efficiency category
Static
Variable speed drive
No
Specific ratio
*
1.00
*
Specific ratio = 1 + p
fs
/ 100 000 Pa
Actual
Request
2013
Request
2015
Overall efficiency η
es
/ %
33.4
28.3
32.3
Efficiency grade N
41.1
36
40
Power input P
e
/ kW
0.61
Air flow q
v
/ m³/h
7510
Pressure increase total p
sf
/ Pa
99
Speed n / min
-1
900
Data definition with optimum efficiency.
The ErP data is determined using a motor-impeller combination in a standardised
measurement configuration.
3.4 Technical features
Mass
27.3 kg
Size
710 mm
Surface of rotor
Cast in aluminium
Material of terminal box
PP plastic
Material of blades
Aluminium sheet insert, sprayed with PP
plastic
Material of wall ring
Sheet steel, galvanised and coated in
black plastic (RAL 9005)
Material of guard grille
Steel, coated in black plastic (RAL9005)
Number of blades
5
Blade angle
-10°
Direction of air flow
"V"
Direction of rotation
Counter-clockwise, seen on rotor
Type of protection
IP 54
Insulation class
"F"
Humidity class
F3-1
Mounting position
Shaft horizontal or rotor on bottom; rotor
on top on request
Condensate discharge
holes
Rotor-side
Operation mode
S1
Motor bearing
Ball bearing
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
<= 3.5 mA
Electrical leads
Via terminal box, integrated capacitor
connected via terminal box
Motor protection
Thermal overload protector (TOP)
brought out
Cable exit
Axial
Protection class
I (if protective earth is connected by
customer)
Product conforming
to standard
EN 61800-5-1; CE
Approval
EAC; VDE
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.5 Mounting data
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.6 Transport and storage conditions
; Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+ 80 °C
Min. permissible
ambient motor temp.
(transp./storage)
- 40 °C
Item no. 10159-5-9970 · Revision 82513 · Release 2014-07-16 · Page 5 / 11