4.3 Connection of the cables

External leads are brought out of device.
; First connect the "PE" (protective earth) connection.

Connect the lines according to your application. When doing so,
observe chapter 4.5 Connection screen.

4.3.1 Cable routing

No water may penetrate along the cable in the direction of the cable exit.

Fans installed lying flat

Fig. 1: Fan installed lying flat, cable routed as a water trap.
; Make sure that the cable is routed in the form of a loop (water trap).
; The bushing must not be kinked during this process.

Fans installed in upright position

Fig. 2: Cable routing for fans installed in upright position.
The cables must always be routed downwards.

4.4 Factory settings

Factory settings with which the device is pre-set by ebm-papst.

Operation mode

PWM controlling

Group adress

01

Fan / device adress

01

Max. PWM / %

100

Min. PWM / %

0

Save set value to
EEPROM

No

Set value control

Analog

Control function

Positive (heating)

Item no. 50394-5-9970 · Revision 83042 · Release 2014-07-09 · Page 7 / 11