beautypg.com

Operating instructions – ebm-papst A4D500-AM01-03 User Manual

Page 5

background image

Operating instructions

A4D500-AM01-03

Translation of the original operating instructions

3.2 Nominal data

Motor

M4D110-GF

Phase

3~

3~

3~

3~

Nominal voltage / VAC

230

230

277

400

Connection

Δ

Δ

Δ

Y

Frequency / Hz

50

60

60

50

Type of data definition

ml

ml

ml

ml

Valid for approval /
standard

CE

CE

CE

CE

Speed / min

-1

1350

1510

1590

1350

Power input / W

690

950

1050

690

Current draw / A

2.34

2.77

2.72

1.35

Max. back pressure / Pa

155

145

160

155

Min. ambient temperature
/ °C

-40

-40

-40

-40

Max. ambient
temperature
/ °C

65

60

60

65

Starting current / A

17.3

16.6

10

Maximum safe operating
speed / min

-1

1920
@ 55 °C

1920
@ 55 °C

1920
@ 55 °C

1920
@ 55 °C

Phase

3~

3~

Nominal voltage / VAC

400

480

Connection

Y

Y

Frequency / Hz

60

60

Type of data definition

ml

ml

Valid for approval /
standard

CE

CE

Speed / min

-1

1510

1590

Power input / W

950

1050

Current draw / A

1.6

1.57

Max. back pressure / Pa

145

160

Min. ambient temperature
/ °C

-40

-40

Max. ambient
temperature
/ °C

60

60

Starting current / A

9.6

Maximum safe operating
speed / min

-1

1920
@ 55 °C

1920
@ 55 °C

ml = Max. load · me = Max. efficiency · fa = Running at free air

cs = Customer specs · cu = Customer unit

Subject to alterations

3.3 Data according to ErP directive

Installation category

A

Efficiency category

Static

Variable speed drive

No

Specific ratio

*

1.00

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Actual

Request
2013

Request
2015

Overall efficiency η

es

/ %

33.3

28.5

32.5

Efficiency grade N

40.8

36

40

Power input P

e

/ kW

0.66

Air flow q

v

/ m³/h

5985

Pressure increase total p

sf

/ Pa

134

Speed n / min

-1

1355

Data definition with optimum efficiency.

The ErP data is determined using a motor-impeller combination in a standardised

measurement configuration.

3.4 Technical features

Mass

9.8 kg

Size

500 mm

Surface of rotor

Coated in black

Material of terminal box

PC / ABS plastic

Material of blades

Press-fitted sheet steel blank, sprayed
with PP plastic

Number of blades

5

Direction of air flow

"V"

Direction of rotation

Counter-clockwise, seen on rotor

Type of protection

IP 54

Insulation class

"F"

Humidity class

F4-1

Mounting position

Shaft horizontal or rotor on bottom; rotor
on top on request

Condensate discharge
holes

Rotor-side

Operation mode

S1

Motor bearing

Ball bearing

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

<= 3.5 mA

Electrical leads

Via terminal box

Motor protection

Thermal overload protector (TOP)
brought out

Cable exit

Axial

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 61800-5-1; CE

Approval

CCC; EAC; UL 1004-1; VDE; CSA
C22.2 Nr.100

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

Item no. 10593-5-9970 · Revision 82543 · Release 2014-05-08 · Page 5 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com