Operating instructions – ebm-papst A4D350-AN08-01 User Manual
Page 5
Operating instructions
A4D350-AN08-01
Translation of the original operating instructions
3.2 Nominal data
Motor
M4D074-DF
Phase
3~
3~
3~
3~
Nominal voltage / VAC
230
230
400
400
Connection
Δ
Δ
Y
Y
Frequency / Hz
50
60
50
60
Type of data definition
ml
ml
ml
ml
Valid for approval /
standard
CE
CE
CE
CE
Speed / min
-1
1370
1520
1370
1520
Power input / W
170
230
170
230
Current draw / A
0.64
0.70
0.37
0.40
Max. back pressure / Pa
90
90
90
90
Min. ambient temperature
/ °C
-25
-25
-25
-25
Max. ambient
temperature
/ °C
65
55
65
55
Starting current / A
1.9
1.9
1.1
1.1
ml = Max. load · me = Max. efficiency · fa = Running at free air
cs = Customer specs · cu = Customer unit
Subject to alterations
3.3 Data according to ErP directive
Installation category
A
Efficiency category
Static
Variable speed drive
No
Specific ratio
*
1.00
*
Specific ratio = 1 + p
fs
/ 100 000 Pa
Actual
Request
2013
Request
2015
Overall efficiency η
es
/ %
28.7
24.6
28.6
Efficiency grade N
40.1
36
40
Power input P
e
/ kW
0.16
Air flow q
v
/ m³/h
2105
Pressure increase total p
sf
/ Pa
82
Speed n / min
-1
1375
Data definition with optimum efficiency.
The ErP data is determined using a motor-impeller combination in a standardised
measurement configuration.
3.4 Technical features
Mass
3.5 kg
Size
350 mm
Surface of rotor
Coated in black
Material of blades
Press-fitted sheet steel blank, sprayed
with PP plastic
Number of blades
5
Direction of air flow
"V"
Direction of rotation
Counter-clockwise, seen on rotor
Type of protection
IP 44; Depending on installation and
position as per EN 60034-5
Insulation class
"F"
Humidity class
F1-2
Mounting position
Shaft horizontal or rotor on bottom; rotor
on top on request
Condensate discharge
holes
Rotor-side
Operation mode
S1
Motor bearing
Ball bearing
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
< 0.75 mA
Cable exit
Variable
Protection class
I (if protective earth is connected by
customer)
Product conforming
to standard
EN 60335-1
Approval
CCC
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.5 Mounting data
For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.6 Transport and storage conditions
; Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+ 80 °C
Min. permissible
ambient motor temp.
(transp./storage)
- 40 °C
Item no. 11658-5-9970 · Revision 79663 · Release 2013-04-22 · Page 5 / 9