beautypg.com

Operating instructions – ebm-papst G3G200-GN26-01 User Manual

Page 9

background image

Operating instructions

G3G200-GN26-01

Translation of the original operating instructions

4.3 Connection screen

No.

Pin

Signal

Function / assignment

ST1

1; 2; 3 L; N; PE

Power supply 115 VAC, 50 - 60 Hz, phase, neutral, protective earth

ST2

1

UB

External voltage 16 - 45 VDC, residual ripple +/- 3.5%, SELV

ST2

2

Tach

Speed monitoring, 3 pulses per revolution, SELV

ST2

3

0 - 10 V

Control input 0 - 10 V, impedance 100k, SELV

ST2

4

PWM

Control input PWM, 1 - 6 kHz, SELV

ST2

5

GND

Power supply 230 VAC, 50 - 60 Hz, phase, neutral, protective earth

Item no. 50367-5-9970 · Revision 68161 · Release 2009-10-09 · Page 9 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com