You can control the blower either via the 0-10 VDC input or the
PWM input. Note: Inputs cannot be used simultaneously.

3.2 Nominal data

Motor

M1G074-CF

Phase

1~

Nominal voltage in VAC

230

Frequency in Hz

50/60

Type of data definition

fa

Speed in min

-1

5830

Power input in W

360

Current draw in A

1.6

Min. ambient
temperature in °C

-25

Max. ambient
temperature in °C

+55

Min. temp. of flow
medium in °C

-25

Max. temp. of flow
medium in °C

+80

ml = max. load · me = max. efficiency · fa = running at free air

cs = customer specs · cu = customer unit

Subject to alterations

3.3 Data acc. to ErP Directive

Installation category

A

Efficiency category

Static

Variable speed drive integrated

Integrated

Specific ratio

*

1,02

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Actual

Request
2013

Request
2015

Overall efficiency η

es

58,8

42

45

Efficiency grade N

74,8

58

61

Power input P

ed

in kW

0,3

Air flow q

v

in m³/h

285

Pressure increase total p

sf

in Pa

2000

Speed n in min

-1

6220

Data established at point of optimum efficiency

3.4 Technical description

Mass

4.5 kg

Size

170 mm

Surface of rotor

Coated in black

Material of protective
cover

Polyflam RPP 374-ND CS1 (UL 97-V0)

Material of impeller

Aluminium sheet

Housing material

Die-cast aluminium

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP 20

Insulation class

"B"

Mounting position

Any

Cooling bore / aperture

Rotor-side

Operation mode

S1

Premix

If gas is premixed in the blower, a
special blower must be used. Contact us
for details.

Motor bearing

Ball bearing

Technical features

- Tach output
- Output 10 VDC, max. 10 mA
- Motor current limit
- PFC, active
- Control input 0-10 VDC / PWM
- Over-temperature protected motor

Leakage current

<= 3.5 mA

Electrical leads

With plug

Motor protection

Thermal overload protector (TOP) wired
internally

Approval

UL 507; CSA C22.2 Nr.113; CCC

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.5 Mounting data

For depth of screw, see chapter 3.1 Graphic rendition of products
; Secure the mounting screws against accidentally coming loose (e.g.

by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.6 Transport and storage conditions

; Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+80 °C

Min. permissible
ambient motor temp.
(transp./storage)

-40 °C

3.7 Electromagnetic compatibility

EMC interference
immunity

Acc. to EN 61000-6-2 (industrial
environment)

EMC interference
emission

Acc. to EN 61000-6-4 (industrial
environment)

EMC harmonics

Acc. to EN 61000-3-2/3

Item no.: 51177-5-9970 · Revision: 73287 · Print-out: 2012-04-11 · Y. Uhlmann (VM-TDO) · Page 6 / 12