Operating instructions

G1G170-AB53-03

Translation of the original operating instructions

4.4 Connection diagram

No.

Pin

Signal

Function / assignment

ST1

1,2,3

L, N, PE

Power supply 230 VAC, 50-60 Hz, neutral conductor, protective earth

ST2

1

UB

External voltage 18-43 VDC

ST2

2

DUE

Speed monitoring output connection, monitoring circuit output, 3 pulses per revolution, current source 2 mA

ST2

3

N.C.

Not assigned

ST2

4

PWM

PWM - 2 - 6 kHz control input, PWM on n = 100%, PWM low n = 0%

ST2

5

GND

GND - Connection for control interface

Item no.: 50130-5-9970 · Revision: 69291 · Print-out: 2012-04-11 · Y. Uhlmann (VM-TDO) · Page 9 / 12