Operating instructions – ebm-papst G1G170-AB31-51 User Manual
Page 6
Operating instructions
G1G170-AB31-51
Translation of the original operating instructions
You can control the blower either via the 0-10 VDC input or the
PWM input. Note: Inputs cannot be used simultaneously.
3.2 Nominal data
Motor
M1G074-CF
Phase
1~
Nominal voltage in VAC
230
Frequency in Hz
50/60
Type of data definition
ml
Speed in min
-1
6530
Power input in W
410
Current draw in A
1.8
Min. back pressure in Pa 2000
Min. ambient
temperature in °C
- 25
Max. ambient
temperature in °C
+55
Min. temp. of flow
medium in °C
-25
Max. temp. of flow
medium in °C
+80
ml = max. load · me = max. efficiency · fa = running at free air
cs = customer specs · cu = customer unit
Subject to alterations
3.3 Data acc. to ErP Directive
Installation category
A
Efficiency category
Static
Variable speed drive integrated
Integrated
Specific ratio
*
1,02
*
Specific ratio = 1 + p
fs
/ 100 000 Pa
Actual
Request
2013
Request
2015
Overall efficiency η
es
57,1
43,4
46,4
Efficiency grade N
71,7
58
61
Power input P
ed
in kW
0,41
Air flow q
v
in m³/h
380
Pressure increase total p
sf
in Pa
2001
Speed n in min
-1
6530
Data established at point of optimum efficiency
3.4 Technical description
Mass
4.7 kg
Size
170 mm
Surface of rotor
Coated in black
Material of protective
cover
Polyflam RPP 374-ND CS1 (UL 97-V0)
Material of impeller
Aluminium sheet
Housing material
Die-cast aluminium
Direction of rotation
Clockwise, seen on rotor
Type of protection
IP 20
Insulation class
"B"
Mounting position
Any
Cooling bore / aperture
Rotor-side
Premix
If gas is premixed in the blower, a
special blower must be used.
Motor bearing
Ball bearing
Technical features
- Tach output
- Motor current limit
- PFC, active
- PWM control input
- Over-temperature protected motor
Leakage current
<= 3.5 mA
Electrical leads
With plug
Motor protection
Thermal overload protector (TOP) wired
internally
Product conforming
to standard
CE
Approval
CSA C22.2 Nr.113; CCC; UL 507
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.5 Mounting data
For depth of screw, see chapter 3.1 Graphic rendition of products
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.6 Transport and storage conditions
; Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+80 °C
Min. permissible
ambient motor temp.
(transp./storage)
-40 °C
3.7 Electromagnetic compatibility
EMC interference
immunity
Acc. to EN 61000-6-2
EMC interference
emission
Acc. to EN 61000-6-4 (industrial
environment)
EMC harmonics
Acc. to EN 61000-3-2/3
Item no.: 50129-5-9970 · Revision: 67913 · Print-out: 2012-04-11 · Y. Uhlmann (VM-TDO) · Page 6 / 12