Operating instructions – ebm-papst G1G170-AB05-20 User Manual
Page 5
Operating instructions
G1G170-AB05-20
Translation of the original operating instructions
You can control the blower either via the 0-10 VDC input or the
PWM input. Note: Inputs cannot be used simultaneously.
3.2 Nominal data
Motor
M1G074-CF
Phase
1~
Nominal voltage / VAC
115
Frequency / Hz
50/60
Type of data definition
fa
Speed / min
-1
5730
Power input / W
345
Current draw / A
4.0
Min. ambient temperature
/ °C
- 25
Max. ambient temperature
/ °C
+ 55
Min. temp. of flow
medium / °C
-25
Max. temp. of flow
medium / °C
+80
ml = Max. load · me = Max. efficiency · fa = Running at free air
cs = Customer specs · cu = Customer unit
Subject to alterations
3.3 Technical features
Mass
4.35 kg
Size
170 mm
Surface of rotor
Coated in black
Material of protective
cover
Polyflam RPP 374-ND CS1 (UL 97-V0)
Material of impeller
Aluminium sheet
Housing material
Die-cast aluminium
Direction of rotation
Clockwise, seen on rotor
Type of protection
IP 20
Insulation class
"B"
Mounting position
Any
Cooling bore / aperture
Rotor-side
Premix
If gas is premixed in the blower, a
special blower must be used.
Motor bearing
Ball bearing
Technical features
- Control input PWM
- Motor current limit
- Tach output
- Overtemperature-protected motor
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
<= 3.5 mA
Electrical leads
With plug
Motor protection
Thermal overload protector (TOP) wired
internally
Approval
UL 507; CSA C22.2 Nr.113
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.4 Mounting data
For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.5 Transport and storage conditions
; Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+80 °C
Min. permissible
ambient motor temp.
(transp./storage)
-40 °C
3.6 Electromagnetic compatibility
EMC interference
immunity
Acc. to EN 61000-6-2
EMC interference
emission
Acc. to EN 61000-6-3 (household
environment)
Item no. 50103-5-9970 · Revision 70943 · Release 2011-03-30 · Page 5 / 11
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com