You can control the blower either via the 0-10 VDC input or the
PWM input. Note: Inputs cannot be used simultaneously.

3.2 Nominal data

Motor

M1G074-CF

Phase

1~

Nominal voltage / VAC

115

Frequency / Hz

50/60

Type of data definition

fa

Speed / min

-1

5730

Power input / W

345

Current draw / A

4.0

Min. ambient temperature
/ °C

- 25

Max. ambient temperature
/ °C

+ 55

Min. temp. of flow
medium / °C

-25

Max. temp. of flow
medium / °C

+80

ml = Max. load · me = Max. efficiency · fa = Running at free air

cs = Customer specs · cu = Customer unit

Subject to alterations

3.3 Technical features

Mass

4.35 kg

Size

170 mm

Surface of rotor

Coated in black

Material of protective
cover

Polyflam RPP 374-ND CS1 (UL 97-V0)

Material of impeller

Aluminium sheet

Housing material

Die-cast aluminium

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP 20

Insulation class

"B"

Mounting position

Any

Cooling bore / aperture

Rotor-side

Premix

If gas is premixed in the blower, a
special blower must be used.

Motor bearing

Ball bearing

Technical features

- Control input PWM
- Motor current limit
- Tach output
- Overtemperature-protected motor

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

<= 3.5 mA

Electrical leads

With plug

Motor protection

Thermal overload protector (TOP) wired
internally

Approval

UL 507; CSA C22.2 Nr.113

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.4 Mounting data

For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.

by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.5 Transport and storage conditions

; Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+80 °C

Min. permissible
ambient motor temp.
(transp./storage)

-40 °C

3.6 Electromagnetic compatibility

EMC interference
immunity

Acc. to EN 61000-6-2

EMC interference
emission

Acc. to EN 61000-6-3 (household
environment)

Item no. 50103-5-9970 · Revision 70943 · Release 2011-03-30 · Page 5 / 11