Operating instructions – ebm-papst R4E250-BA09-03 User Manual
Page 5

Operating instructions
R4E250-BA09-03
Translation of the original operating instructions
3.2 Nominal data
Motor
M4E094-HA
Phase
1~
1~
Nominal voltage / VAC
230
230
Frequency / Hz
50
60
Type of data definition
fa
ml
Valid for approval /
standard
CE
CE
Speed / min
-1
1310
1470
Power input / W
570
690
Current draw / A
2.48
3.05
Motor capacitor / µF
10
10
Capacitor voltage / VDB
450
450
Min. back pressure / Pa
0
100
Min. ambient temperature
/ °C
-40
-40
Max. ambient
temperature
/ °C
70
55
Starting current / A
6
5.1
Maximum safe operating
speed / min
-1
1950
1950
ml = Max. load · me = Max. efficiency · fa = Running at free air
cs = Customer specs · cu = Customer unit
Subject to alterations
3.3 Data according to ErP directive
Installation category
B
Efficiency category
Total
Variable speed drive
No
Specific ratio
*
1.00
*
Specific ratio = 1 + p
f
/ 100 000 Pa
Actual
Request
2013
Request
2015
Overall efficiency η
e
/ %
36.2
32.6
39.6
Efficiency grade N
45.6
42
49
Power input P
e
/ kW
0.33
Air flow q
v
/ m³/h
1165
Pressure increase total p
sf
/ Pa
379
Speed n / min
-1
1420
Data definition with optimum efficiency.
The ErP data is determined using a motor-impeller combination in a standardised
measurement configuration.
3.4 Technical features
Mass
8.5 kg
Size
250 mm
Surface of rotor
Coated in black
Material of impeller
Sheet steel, hot-dip galvanised
Direction of rotation
Clockwise, seen on rotor
Type of protection
IP 54
Insulation class
"F"
Humidity class
F4-1
Mounting position
Shaft horizontal or rotor on bottom; rotor
on top on request
Condensate discharge
holes
None
Operation mode
S1
Motor bearing
Ball bearing
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
<= 3.5 mA
Motor protection
Thermal overload protector (TOP)
brought out
Cable exit
Variable
Protection class
I (if protective earth is connected by
customer)
Product conforming
to standard
EN 60034-1 (2004)
Approval
CCC; EAC
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.5 Mounting data
For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.6 Transport and storage conditions
; Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+80 °C
Min. permissible
ambient motor temp.
(transp./storage)
-40 °C
Item no. 10714-5-9970 · Revision 82623 · Release 2014-05-08 · Page 5 / 10
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com