Operating instructions – ebm-papst R4D225-AK10-06 User Manual
Page 5
![background image](/manuals/673367/5/background.png)
Operating instructions
R4D225-AK10-06
Translation of the original operating instructions
3.2 Nominal data
Motor
M4D094-FA
Phase
3~
3~
Nominal voltage / VAC
400
400
Connection
Y
Y
Frequency / Hz
50
60
Type of data definition
ml
ml
Valid for approval /
standard
CE
CE
Speed / min
-1
1350
1500
Power input / W
380
540
Current draw / A
0.75
0.94
Min. back pressure / Pa
0
50
Min. ambient temperature
/ °C
-40
-40
Max. ambient
temperature
/ °C
90
60
Starting current / A
2.8
2.7
ml = Max. load · me = Max. efficiency · fa = Running at free air
cs = Customer specs · cu = Customer unit
Subject to alterations
3.3 Data according to ErP directive
Installation category
B
Efficiency category
Total
Variable speed drive
No
Specific ratio
*
1.00
*
Specific ratio = 1 + p
f
/ 100 000 Pa
Actual
Request
2013
Request
2015
Overall efficiency η
e
/ %
40.3
31.4
38.4
Efficiency grade N
50.9
42
49
Power input P
e
/ kW
0.21
Air flow q
v
/ m³/h
910
Pressure increase total p
sf
/ Pa
340
Speed n / min
-1
1430
Data definition with optimum efficiency.
The ErP data is determined using a motor-impeller combination in a standardised
measurement configuration.
3.4 Technical features
Mass
6.03 kg
Size
225 mm
Surface of rotor
Coated in black
Material of impeller
Sheet steel, galvanised
Direction of rotation
Clockwise, seen on rotor
Type of protection
IP 54
Insulation class
"F"
Humidity class
F4-1
Mounting position
Any
Condensate discharge
holes
None
Operation mode
S1
Motor bearing
Ball bearing
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
<= 3.5 mA
Motor protection
Thermal overload protector (TOP)
brought out
Cable exit
Variable
Protection class
I (if protective earth is connected by
customer)
Product conforming
to standard
EN 60034-1 (2004); CE
Approval
EAC
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.5 Mounting data
For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.6 Transport and storage conditions
; Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+80 °C
Min. permissible
ambient motor temp.
(transp./storage)
-40 °C
Item no. 10710-5-9970 · Revision 82546 · Release 2014-05-08 · Page 5 / 10