beautypg.com

Operating instructions – ebm-papst G4E180-GS11-01 User Manual

Page 5

background image

Operating instructions

G4E180-GS11-01

Translation of the original operating instructions

3.2 Nominal data

Motor

M4E074-DF

Phase

1~

1~

Nominal voltage / VAC

230

230

Frequency / Hz

50

60

Type of data definition

fa

ml

Valid for approval /
standard

CE

CE

Speed / min

-1

1130

1170

Power input / W

180

200

Current draw / A

0.8

0.88

Motor capacitor / µF

4

4

Capacitor voltage / VDB

400

400

Min. back pressure / Pa

0

50

Max. ambient
temperature / °C

45

35

ml = max. load · me = max. efficiency · fa = running at free air

cs = customer specs · cu = customer unit

Subject to alterations

3.3 Technical features

Mass

6.1 kg

Size

180 mm

Surface of rotor

Coated in black

Material of impeller

Sheet steel, galvanized

Housing material

Sheet steel, galvanized

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP 44

Insulation class

"B"

Humidity class

F5

Mounting position

Any

Condensate discharge
holes

Rotor-side

Operation mode

S1

Motor bearing

Ball bearing

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

< 0.75 mA

Motor protection

Thermal overload protector (TOP) wired
internally

Cable exit

Axial

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 60335-1; CE

Approval

CCC

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.4 Mounting data

For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.

by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.5 Transport and storage conditions

; Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

Item no. 10302-5-9970 · Revision 72138 · Release 2010-11-12 · Page 5 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com