3.2 Nominal data
Motor
M4D074-EI
Phase
3~
3~
3~
3~
Nominal voltage / VAC
230
230
400
400
Connection
Δ
Δ
Y
Y
Frequency / Hz
50
60
50
60
Type of data definition
fa
ml
fa
ml
Valid for approval /
standard
CE
CE
CE
CE
Speed / min
-1
1350
1530
1350
1530
Power input / W
285
360
285
360
Current draw / A
1.0
1.13
0.58
0.65
Min. back pressure / Pa
0
200
0
200
Min. ambient temperature
/ °C
-25
-25
-25
-25
Max. ambient
temperature
/ °C
45
45
45
45
ml = Max. load · me = Max. efficiency · fa = Running at free air
cs = Customer specs · cu = Customer unit
Subject to alterations
3.3 Data according to ErP directive
Installation category
A
Efficiency category
Static
Variable speed drive
No
Specific ratio
*
1.00
*
Specific ratio = 1 + p
fs
/ 100 000 Pa
Actual
Request
2013
Request
2015
Overall efficiency η
es
/ %
29.5
25.8
32.8
Efficiency grade N
40.7
37
44
Power input P
e
/ kW
0.17
Air flow q
v
/ m³/h
805
Pressure increase total p
sf
/ Pa
234
Speed n / min
-1
1425
Data definition with optimum efficiency.
The ErP data is determined using a motor-impeller combination in a standardised
measurement configuration.
3.4 Technical features
Mass
7.2 kg
Size
200 mm
Surface of rotor
Coated in black
Material of impeller
Sheet steel, coated in black
Housing material
Sheet steel, galvanised
Direction of rotation
Clockwise, seen on rotor
Type of protection
IP 44; Depending on installation and
position as per EN 60034-5
Insulation class
"B"
Humidity class
F1-2
Mounting position
Shaft horizontal or rotor on bottom; rotor
on top on request
Condensate discharge
holes
Rotor-side
Operation mode
S1
Motor bearing
Ball bearing
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
< 0.75 mA
Cable exit
Axial
Protection class
I (if protective earth is connected by
customer)
Product conforming
to standard
EN 60335-1, motor does not have
factory-installed overheating protection
Approval
CCC
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.5 Mounting data
For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.6 Transport and storage conditions
; Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+ 80 °C
Min. permissible
ambient motor temp.
(transp./storage)
- 40 °C
Item no. 11435-5-9970 · Revision 79127 · Release 2014-01-10 · Page 5 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com