3.2 Nominal data

Motor

M4D074-EI

Phase

3~

3~

3~

3~

Nominal voltage / VAC

230

230

400

400

Connection

Δ

Δ

Y

Y

Frequency / Hz

50

60

50

60

Type of data definition

fa

ml

fa

ml

Valid for approval /
standard

CE

CE

CE

CE

Speed / min

-1

1350

1530

1350

1530

Power input / W

285

360

285

360

Current draw / A

1.0

1.13

0.58

0.65

Min. back pressure / Pa

0

200

0

200

Min. ambient temperature
/ °C

-25

-25

-25

-25

Max. ambient
temperature
/ °C

45

45

45

45

ml = Max. load · me = Max. efficiency · fa = Running at free air

cs = Customer specs · cu = Customer unit

Subject to alterations

3.3 Data according to ErP directive

Installation category

A

Efficiency category

Static

Variable speed drive

No

Specific ratio

*

1.00

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Actual

Request
2013

Request
2015

Overall efficiency η

es

/ %

29.5

25.8

32.8

Efficiency grade N

40.7

37

44

Power input P

e

/ kW

0.17

Air flow q

v

/ m³/h

805

Pressure increase total p

sf

/ Pa

234

Speed n / min

-1

1425

Data definition with optimum efficiency.

The ErP data is determined using a motor-impeller combination in a standardised

measurement configuration.

3.4 Technical features

Mass

7.2 kg

Size

200 mm

Surface of rotor

Coated in black

Material of impeller

Sheet steel, coated in black

Housing material

Sheet steel, galvanised

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP 44; Depending on installation and
position as per EN 60034-5

Insulation class

"B"

Humidity class

F1-2

Mounting position

Shaft horizontal or rotor on bottom; rotor
on top on request

Condensate discharge
holes

Rotor-side

Operation mode

S1

Motor bearing

Ball bearing

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

< 0.75 mA

Cable exit

Axial

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 60335-1, motor does not have
factory-installed overheating protection

Approval

CCC

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.5 Mounting data

For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.

by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.6 Transport and storage conditions

; Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C