Operating instructions – ebm-papst G2E133-DN77-01 User Manual
Page 5
Operating instructions
G2E133-DN77-01
Translation of the original operating instructions
3.2 Nominal data
Motor
M2E068-BF
Phase
1~
1~
Nominal voltage / VAC
230
230
Frequency / Hz
50
60
Type of data definition
fa
fa
Valid for approval /
standard
CE
CE
Speed / min
-1
2150
2100
Power input / W
88
110
Current draw / A
0.39
0.49
Motor capacitor / µF
2
2
Capacitor voltage / VDB
450
450
Min. back pressure / Pa
0
0
Min. ambient
temperature / °C
-25
-25
Max. ambient
temperature / °C
55
50
ml = max. load · me = max. efficiency · fa = running at free air
cs = customer specs · cu = customer unit
Subject to alterations
3.3 Technical features
Mass
1.9 kg
Size
133 mm
Surface of rotor
Partially cast in aluminium
Material of impeller
Sendzimir galvanized sheet steel
Housing material
Sheet steel, hot-galvanised
Direction of rotation
Clockwise, seen on rotor
Type of protection
IP 44
Insulation class
"B"
Humidity class
F0
Mounting position
Any
Condensate discharge
holes
None
Operation mode
S1
Motor bearing
Ball bearing
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
< 0.75 mA
Motor protection
Thermal overload protector (TOP) wired
internally
Cable exit
Variable
Protection class
I (if protective earth is connected by
customer)
Product conforming
to standard
EN 60335-1; CE
Approval
CCC
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.4 Mounting data
For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.5 Transport and storage conditions
; Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+ 80 °C
Min. permissible
ambient motor temp.
(transp./storage)
- 40 °C
Item no. 11012-5-9970 · Revision 71618 · Release 2010-10-19 · Page 5 / 9