beautypg.com

Operating instructions – ebm-papst D4E160-DA01-22 User Manual

Page 5

background image

Operating instructions

D4E160-DA01-22

Translation of the original operating instructions

3.2 Nominal data

Motor

M4E068-DF

Phase

1~

1~

Nominal voltage / VAC

230

230

Frequency / Hz

50

60

Type of data definition

fa

fa

Valid for approval /
standard

CE

CE

Speed / min

-1

1100

1100

Power input / W

120

145

Current draw / A

0.53

0.64

Motor capacitor / µF

3

3

Capacitor voltage / VDB

450

450

Min. back pressure / Pa

0

0

Min. ambient temperature
/ °C

-25

-25

Max. ambient
temperature
/ °C

60

40

Starting current / A

0.72

0.72

ml = Max. load · me = Max. efficiency · fa = Running at free air

cs = Customer specs · cu = Customer unit

Subject to alterations

3.3 Technical features

Mass

4 kg

Size

160 mm

Material of impeller

Sheet steel, galvanised

Housing material

Sheet steel, galvanised

Motor suspension

Motor anti-vibration mounted on one side
via brackets

Direction of rotation

Counter-clockwise, seen on rotor

Type of protection

IP 44; Depending on installation and
position

Insulation class

"B"

Humidity class

F0

Mounting position

Any

Condensate discharge
holes

None

Operation mode

S1

Motor bearing

Ball bearing

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

< 0.75 mA

Motor protection

Thermal overload protector (TOP) wired
internally

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 60335-1; CE

Approval

CCC

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.4 Mounting data

For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.

by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.5 Transport and storage conditions

; Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

Item no. 11653-5-9970 · Revision 75033 · Release 2014-04-15 · Page 5 / 9