Operating instructions – ebm-papst D3G283-AB37-01 User Manual
Page 5

Operating instructions
D3G283-AB37-01
Translation of the original operating instructions
3.2 Nominal data
Motor
M3G112-GA
Phase
3~
Nominal voltage / VAC
400
Nominal voltage
range / VAC
380 .. 480
Type of data definition
ml
State
prelim.
Speed / min
-1
1220
Power input / W
1000
Current draw / A
1.7
Min. back pressure / Pa
270
Min. ambient temperature
/ °C
-25
Max. ambient
temperature
/ °C
40
ml = Max. load · me = Max. efficiency · fa = Running at free air
cs = Customer specs · cu = Customer unit
Subject to alterations
3.3 Data according to ErP directive
Installation category
A
Efficiency category
Static
Variable speed drive
Yes
Specific ratio
*
1.01
*
Specific ratio = 1 + p
fs
/ 100 000 Pa
Actual
Request
2013
Request
2015
Overall efficiency η
es
/ %
52.4
29.1
36.1
Efficiency grade N
60.3
37
44
Power input P
ed
/ kW
0.56
Air flow q
v
/ m³/h
1995
Pressure increase total p
sf
/ Pa
485
Speed n / min
-1
1390
Data definition with optimum efficiency.
The ErP data is determined using a motor-impeller combination in a standardised
measurement configuration.
3.4 Technical features
Mass
18.6 kg
Size
283 mm
Surface of rotor
Coated in black
Material of electronics
housing
Die-cast aluminium
Material of impeller
Sheet steel, galvanised
Housing material
Sheet steel, galvanised
Motor suspension
Motor anti-vibration mounted on one side
via brackets
Direction of rotation
Clockwise, seen on rotor
Type of protection
IP 54
Insulation class
"B"
Humidity class
F4-1
Mounting position
Shaft horizontal
Condensate discharge
holes
None
Operation mode
S1
Motor bearing
Ball bearing
Technical features
- Output 10 VDC, max. 10 mA
- Alarm relay
- Integrated PID controller
- Motor current limit
- PFC, passive
- Soft start
- Control input 0-10 VDC / PWM
- Control interface with SELV potential
safely disconnected from the mains
- Over-temperature protected
electronics / motor
- Line undervoltage / phase failure
detection
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
<= 3.5 mA
Motor protection
Thermal overload protector (TOP) wired
internally
Cable exit
Variable
Protection class
I (if protective earth is connected by
customer)
Product conforming
to standard
CE
Approval
EAC
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.5 Mounting data
For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.6 Transport and storage conditions
; Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+80 °C
Min. permissible
ambient motor temp.
(transp./storage)
-40 °C
Item no. 50383-5-9970 · Revision 82547 · Release 2014-05-08 · Page 5 / 11