beautypg.com

Operating instructions – ebm-papst D3G146-LT13-01 User Manual

Page 8

background image

Operating instructions

D3G146-LT13-01

Translation of the original operating instructions

4.4 Connection screen

No.

Conn.

Designation

Colour

Function / assignment

CON10

10.1

PE

Protective earth

CON10

10.2

L

black

Power supply 230 VAC, 50-60 Hz, see type plate for voltage range

CON10

10.3

N

Neutral conductor

CON11

11.1

10 V/max. 1.1
mA

Voltage output 10 V, 1.1 mA, electrically isolated, not short-circuit-proof

CON11

11.2

Tach

Tach output: Open collector, 1 pulse per revolution, electrically isolated, Isink max = 10 mA

CON11

11.3

0-10 V PWM

yellow

Control input 0-10 V or PWM, electrically isolated

CON11

11.4

GND

blue

GND connection for control interface

Item no. 51142-5-9970 · ENG · Revision 83605 · Release 2014-11-03 · Page 8 / 10