3.2 Nominal data

Motor

M2E068-EC

Phase

1~

1~

Nominal voltage / VAC

230

230

Frequency / Hz

50

60

Type of data definition

ml

ml

Valid for approval /
standard

CE

CE

Speed / min

-1

1850

2100

Power input / W

355

400

Current draw / A

1.55

1.75

Motor capacitor / µF

8

8

Capacitor voltage / VDB 450

450

Capacitor standard

P2 (CE)

P2 (CE)

Min. back pressure / Pa

0

200

Min. ambient temperature
/ °C

-25

-25

Max. ambient
temperature
/ °C

55

50

Starting current / A

1.8

1.9

ml = Max. load · me = Max. efficiency · fa = Running at free air

cs = Customer specs · cu = Customer unit

Subject to alterations

3.3 Data according to ErP directive

Installation category

A

Efficiency category

Static

Variable speed drive

No

Specific ratio

*

1.00

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Actual

Request
2013

Request
2015

Overall efficiency η

es

/ %

29

27

34

Efficiency grade N

39

37

44

Power input P

e

/ kW

0.26

Air flow q

v

/ m³/h

700

Pressure increase total p

sf

/ Pa

400

Speed n / min

-1

2435

Data definition with optimum efficiency.

The ErP data is determined using a motor-impeller combination in a standardised

measurement configuration.

3.4 Technical features

Mass

3.4 kg

Size

146 mm

Surface of rotor

Partially cast in aluminium

Material of terminal box PP plastic, black
Material of impeller

Sheet steel, hot-dip galvanised

Housing material

PP plastic, black

Motor suspension

Motor mounted with anti-vibration on both
sides

Direction of rotation

Counter-clockwise, seen on rotor

Type of protection

IP 20

Insulation class

"F"

Humidity class

F0

Mounting position

Any

Condensate discharge
holes

None, open rotor

Operation mode

S1

Motor bearing

Ball bearing

Speed steps

4

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

< 0.75 mA

Electrical leads

Via terminal box, integrated capacitor
connected via terminal box; With plug

Motor protection

Thermal overload protector (TOP) wired
internally

Cable exit

Variable

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 60335-2-31; CE

Approval

CCC; VDE

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.5 Mounting data

For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.

by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.6 Transport and storage conditions

; Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

Item no. 10392-5-9970 · Revision 76573 · Release 2014-02-28 · Page 5 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com