3.2 Nominal data
Motor
M2E068-EC
Phase
1~
1~
Nominal voltage / VAC
230
230
Frequency / Hz
50
60
Type of data definition
ml
ml
Valid for approval /
standard
CE
CE
Speed / min
-1
2050
2550
Power input / W
300
330
Current draw / A
1.31
1.45
Motor capacitor / µF
8
8
Capacitor voltage / VDB 400
400
Capacitor standard
P0 (CE)
P0 (CE)
Min. back pressure / Pa
200
400
Min. ambient temperature
/ °C
-25
-25
Max. ambient
temperature
/ °C
30
25
ml = Max. load · me = Max. efficiency · fa = Running at free air
cs = Customer specs · cu = Customer unit
Subject to alterations
3.3 Data according to ErP directive
Installation category
A
Efficiency category
Static
Variable speed drive
No
Specific ratio
*
1.00
*
Specific ratio = 1 + p
fs
/ 100 000 Pa
Actual
Request
2013
Request
2015
Overall efficiency η
es
/ %
28.2
26.8
33.8
Efficiency grade N
38.4
37
44
Power input P
e
/ kW
0.24
Air flow q
v
/ m³/h
705
Pressure increase total p
sf
/ Pa
351
Speed n / min
-1
2435
Data definition with optimum efficiency.
The ErP data is determined using a motor-impeller combination in a standardised
measurement configuration.
3.4 Technical features
Mass
4.4 kg
Size
146 mm
Surface of rotor
Uncoated
Material of impeller
Sheet steel, galvanised
Housing material
Sheet steel, galvanised
Motor suspension
Motor mounted via brackets on one side
Direction of rotation
Counter-clockwise, seen on rotor
Type of protection
IP 44; Depending on installation and
position
Insulation class
"B"
Humidity class
F0
Mounting position
Any
Condensate discharge
holes
None
Operation mode
S1
Motor bearing
Ball bearing
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
< 0.75 mA
Motor protection
Thermal overload protector (TOP) wired
internally
Cable exit
Axial
Protection class
I (if protective earth is connected by
customer)
Product conforming
to standard
CE
Approval
CCC; GOST
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.5 Mounting data
For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.6 Transport and storage conditions
; Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+ 80 °C
Min. permissible
ambient motor temp.
(transp./storage)
- 40 °C
Item no. 10541-5-9970 · Revision 80019 · Release 2014-02-20 · Page 5 / 9