3.2 Nominal data
Motor
M2E052-BF
Phase
1~
1~
Nominal voltage / VAC
230
230
Frequency / Hz
50
60
Type of data definition
fa
fa
Valid for approval /
standard
CE
CE
Speed / min
-1
1550
1450
Power input / W
28
32
Current draw / A
0.13
0.15
Motor capacitor / µF
1
1
Capacitor voltage / VDB
400
400
Capacitor standard
P0 (CE)
P0 (CE)
Min. back pressure / Pa
0
0
Max. ambient
temperature / °C
85
80
ml = max. load · me = max. efficiency · fa = running at free air
cs = customer specs · cu = customer unit
Subject to alterations
3.3 Technical features
Mass
1.2 kg
Size
97 mm
Surface of rotor
Coated in black
Material of impeller
Sheet steel, hot-galvanised
Housing material
Sheet steel, hot-galvanised
Direction of rotation
Counter-clockwise, seen on rotor
Type of protection
IP 20
Insulation class
"B"
Mounting position
Shaft horizontal or rotor on bottom; rotor
on top on request
Condensate discharge
holes
Rotor-side
Operation mode
S1
Motor bearing
Ball bearing
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
< 0.75 mA
Motor protection
Thermal overload protector (TOP) wired
internally
Protection class
I (if protective earth is connected by
customer)
Product conforming
to standard
EN 60335-1; CE
Approval
CCC
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.4 Mounting data
For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.5 Transport and storage conditions
; Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+ 80 °C
Min. permissible
ambient motor temp.
(transp./storage)
- 40 °C
Item no. 11332-5-9970 · Revision 73098 · Release 2011-01-25 · Page 5 / 9