3.2 Nominal data
Motor
M3G074-CF
Nominal voltage / VDC
24
Nominal voltage
range / VDC
16 .. 28
Type of data definition
fa
State
prelim.
Speed / min
-1
4060
Power input / W
185
Current draw / A
7.7
Max. back pressure / Pa
450
Min. ambient
temperature / °C
-25
Max. ambient
temperature / °C
+65
ml = max. load · me = max. efficiency · fa = running at free air
cs = customer specs · cu = customer unit
Subject to alterations
3.3 Data according to ErP directive
Installation category
A
Efficiency category
Static
Variable speed drive
Yes
Specific ratio
*
1.00
*
Specific ratio = 1 + p
fs
/ 100 000 Pa
Actual
Request
2013
Request
2015
Overall efficiency η
es
45.2
28.9
31.9
Efficiency grade N
63.3
47
50
Power input P
e
/ kW
0.19
Air flow q
v
/ m³/h
700
Pressure increase total p
sf
/ Pa
409
Speed n / min
-1
3975
Data established at point of optimum efficiency
3.4 Technical features
Mass
2.24 kg
Size
200 mm
Surface of rotor
Coated in black
Material of impeller
PA plastic
Housing material
PA plastic
Material of support
bracket
PA plastic
Number of blades
7
Direction of air flow
"V"
Direction of rotation
Clockwise, seen on rotor
Type of protection
IP 20
Insulation class
"B"
Humidity class
F0
Mounting position
Any
Cooling bore / aperture
Rotor-side
Operation mode
S1
Motor bearing
Ball bearing
Technical features
- Tach output
- Motor current limit
- Soft start
- Control input 0-10 VDC / PWM
- Over-temperature protected electronics
Motor protection
Reverse polarity and locked-rotor
protection
Cable exit
Lateral
Product conforming
to standard
EN 60335-1
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.5 Mounting data
For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.6 Transport and storage conditions
; Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+ 80 °C
Min. permissible
ambient motor temp.
(transp./storage)
- 40 °C
3.7 Electromagnetic compatibility
EMC interference
immunity
Acc. to EN 61000-6-2 (industrial
environment)
EMC interference
emission
Acc. to EN 55022 (Class B, household
environment)
Item no. 50966-5-9970 · Revision 74201 · Release 2012-07-11 · Page 5 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com