beautypg.com

Operating instructions – ebm-papst K3G200-BDA1-02 User Manual

Page 5

background image

Operating instructions

K3G200-BDA1-02

Translation of the original operating instructions

3.2 Nominal data

Motor

M3G074-CF

Nominal voltage / VDC

24

Nominal voltage
range / VDC

16 .. 28

Type of data definition

fa

State

prelim.

Speed / min

-1

4060

Power input / W

185

Current draw / A

7.7

Max. back pressure / Pa

450

Min. ambient
temperature / °C

-25

Max. ambient
temperature / °C

+65

ml = max. load · me = max. efficiency · fa = running at free air

cs = customer specs · cu = customer unit

Subject to alterations

3.3 Data according to ErP directive

Installation category

A

Efficiency category

Static

Variable speed drive

Yes

Specific ratio

*

1.00

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Actual

Request
2013

Request
2015

Overall efficiency η

es

45.2

28.9

31.9

Efficiency grade N

63.3

47

50

Power input P

e

/ kW

0.19

Air flow q

v

/ m³/h

700

Pressure increase total p

sf

/ Pa

409

Speed n / min

-1

3975

Data established at point of optimum efficiency

3.4 Technical features

Mass

2.24 kg

Size

200 mm

Surface of rotor

Coated in black

Material of impeller

PA plastic

Housing material

PA plastic

Material of support
bracket

PA plastic

Number of blades

7

Direction of air flow

"V"

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP 20

Insulation class

"B"

Humidity class

F0

Mounting position

Any

Cooling bore / aperture

Rotor-side

Operation mode

S1

Motor bearing

Ball bearing

Technical features

- Tach output
- Motor current limit
- Soft start
- Control input 0-10 VDC / PWM
- Over-temperature protected electronics

Motor protection

Reverse polarity and locked-rotor
protection

Cable exit

Lateral

Product conforming
to standard

EN 60335-1

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.5 Mounting data

For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.

by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.6 Transport and storage conditions

; Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

3.7 Electromagnetic compatibility

EMC interference
immunity

Acc. to EN 61000-6-2 (industrial
environment)

EMC interference
emission

Acc. to EN 55022 (Class B, household
environment)

Item no. 50966-5-9970 · Revision 74201 · Release 2012-07-11 · Page 5 / 9