3.2 Nominal data

Motor

M1G074-BF

Nominal voltage / VDC

24

Nominal voltage
range / VDC

16 .. 28

Type of data definition

fa

State

prelim.

Speed / min

-1

3400

Power input / W

95

Current draw / A

4.7

Max. back pressure / Pa

355

Min. ambient temperature
/ °C

-25

Max. ambient
temperature
/ °C

60

ml = Max. load · me = Max. efficiency · fa = Running at free air

cs = Customer specs · cu = Customer unit

Subject to alterations

3.3 Technical features

Mass

1.8 kg

Size

200 mm

Surface of rotor

Coated in black

Material of impeller

Plastic PA6, fibreglass-reinforced

Housing material

Plastic PA6, fibreglass-reinforced

Material of support
bracket

Plastic PA6, fibreglass-reinforced

Number of blades

7

Direction of air flow

"V"

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP 44; Depending on installation and
position

Insulation class

"B"

Humidity class

F4-1

Mounting position

Any

Condensate discharge
holes

None

Operation mode

S1

Motor bearing

Ball bearing

Technical features

- Tach output
- Motor current limit
- Soft start
- Control input 0-10 VDC / PWM

Motor protection

Reverse polarity and locked-rotor
protection

Cable exit

Lateral

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 60335-1

Approval

CSA C22.2 Nr.77; UL 1004-1

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.4 Mounting data

For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.

by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.5 Transport and storage conditions

; Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

3.6 Electromagnetic compatibility

EMC interference
immunity

Acc. to EN 61000-6-2 (industrial
environment)

EMC interference
emission

Acc. to EN 55022 (Class B)

Item no. 50900-5-9970 · Revision 70035 · Release 2014-06-13 · Page 5 / 9