3.2 Nominal data
Motor
M2E068-CF
Phase
1~
1~
Nominal voltage / VAC
230
230
Frequency / Hz
50
60
Type of data definition
fa
fa
Valid for approval /
standard
CE
CE
Speed / min
-1
2550
2700
Power input / W
127
180
Current draw / A
0.56
0.79
Motor capacitor / µF
4
4
Capacitor voltage / VDB
400
400
Capacitor standard
P0 (CE)
P0 (CE)
Max. back pressure / Pa
100
100
Min. ambient temperature
/ °C
-25
-25
Max. ambient
temperature
/ °C
60
45
Starting current / A
0.88
0.87
ml = Max. load · me = Max. efficiency · fa = Running at free air
cs = Customer specs · cu = Customer unit
Subject to alterations
3.3 Data according to ErP directive
Installation category
A
Efficiency category
Static
Variable speed drive
No
Specific ratio
*
1.00
*
Specific ratio = 1 + p
fs
/ 100 000 Pa
Actual
Request
2013
Request
2015
Overall efficiency η
es
/ %
26.5
24.3
28.3
Efficiency grade N
38.2
36
40
Power input P
e
/ kW
0.14
Air flow q
v
/ m³/h
1205
Pressure increase total p
sf
/ Pa
115
Speed n / min
-1
2365
Data definition with optimum efficiency.
The ErP data is determined using a motor-impeller combination in a standardised
measurement configuration.
3.4 Technical features
Mass
2.8 kg
Size
250 mm
Surface of rotor
Coated in black
Material of blades
Sheet steel, coated in black
Material of wall ring
Die-cast aluminium
Number of blades
7
Direction of air flow
"V"
Direction of rotation
Counter-clockwise, seen on rotor
Type of protection
IP 44
Insulation class
"F"
Humidity class
F0
Mounting position
any
Condensate discharge
holes
None
Operation mode
S1
Motor bearing
Ball bearing
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
< 0.75 mA
Electrical leads
Via terminal strips, integrated capacitor
connected via terminal strips
Motor protection
Thermal overload protector (TOP) wired
internally
Cable exit
Variable
Protection class
I (if protective earth is connected by
customer)
Product conforming
to standard
EN 60335-1; CE
Approval
CCC; CSA C22.2 Nr.77; EAC; UL 2111
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.5 Mounting data
For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.6 Transport and storage conditions
; Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+ 80 °C
Min. permissible
ambient motor temp.
(transp./storage)
- 40 °C