Eagle Microsystems VF100 User Manual
Page 10

SERIES VF-100 SCREW FEEDER
9
Agitator Eccentric (Flexible wall agitation option only): The agitator eccentric is mounted
to the motor shaft behind the drive coupling. It is subject to wear and should be checked
as part of a preventive maintenance routine. To check the eccentric, remove main
power from the feeder controller. Remove the drive guard. If more than 1/8” free play
side to side is observed between the eccentric and the follower “Fingers”, replace the
eccentric
Hopper Membrane (Flexible wall agitation option only): Inspect the membrane from time
to time for splitting or brittleness. Replace as required.
GEARMOTOR
AGITATOR DRIVE ASSEMBLY, FIG-3
ECCENTRIC, P/N 410033
DRIVE RODS, P/N 410126
AGITATOR BEARINGS, P/N 410028
DRIVE SHAFT
CRANK ARM, P/N 410037