DS501 OPERATORS’ MANUAL

1

SAFETY CONSIDERATIONS

CAUTION - MAINS FUSE

TO REDUCE THE RISK OF FIRE REPLACE THE MAINS FUSE ONLY WITH THE SAME

TYPE, WHICH MUST BE A CLASS 3, 230 VOLT, TIME DELAY TYPE, RATED AT 80mA

WHERE THE MAINS INPUT VOLTAGE SWITCH IS SET TO 230 VOLTS AC. AND

160mA WHERE THE MAINS INPUT VOLTAGE IS 115 VOLTS AC.

ALL FUSES MUST

COMPLY WITH IEC 60127-2. THE FUSE BODY SIZE IS 20mm x 5mm.

CAUTION - MAINS CABLE

DO NOT

ATTEMPT TO CHANGE OR TAMPER WITH THE SUPPLIED MAINS CABLE.

CAUTION - SERVICING

DO NOT

PERFORM ANY SERVICING. REFER ALL SERVICING TO

QUALIFIED SERVICE PERSONNEL.

WARNING

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS

EQUIPMENT TO RAIN OR MOISTURE.

INSTALLATION

This product is designed for standard 19" rack mounting and occupies 1U of rack

space. Use four M6 pan head screws to secure the unit into the rack. Fibre or plastic

washers may be used to prevent the front panel becoming marked by the mounting

bolts.
!

Care should be taken in the choice of positioning. The unit should not be

mounted where other equipment obstructs the normal air flow.

Avoid mounting the unit directly above power amplifiers or power supplies

that radiate significant amounts of heat.

!

The DS501 should not be operated near any water or in a location where

moisture might be present.