beautypg.com

Eq features, D.w. fearn vt-4 vacuum tube lc equalizer 11 – D.W. Fearn VT-4 User Manual

Page 7

background image

D.W. Fearn VT-4 Vacuum Tube LC Equalizer 11

EQ FEATURES

(All controls are independent and can be used in any combination)

Low Cut at 30, 40, 100, or 400 Hz,

0 to -18 dB shelving in 2 dB steps

Low Boost at 20, 40, 60, or 140 Hz,

0 to 12 dB shelving in 2 dB steps

Mid Cut at 200, 300, 400, 500, 600,

or 700 Hz, 0 to -16 dB in 2 dB steps

High Boost at 2, 3, 4, 5, 8, 10, 12, or 16 kHz,

0 to 14 dB in 2 dB steps

High Bandwidth Q of 0.6, 0.8, 1.0, 1.4, or 1.7

High Frequency Cut at 1.7, 4, 10, or 28 kHz,

0 to -14 dB shelving in 2 dB steps

Gain adjustable from -9 to +9 dB,

referenced to +4 dBm, in 3 dB steps

Note: Throughout this manual, frequency is specified in cps (cycles per second) or kc

(kilocycles per second). These units of measurement correspond to Hz and kHz respec-

tively. Specifications subject to change without notice