6technical data – Carl Zeiss Camera Lens User Manual
Page 11
![background image](/manuals/67003/11/background.png)
Sharp Max
Carl Zeiss
Camera Lens Division
Bedienungsanleitung Sharp Max 12_02E.doc Status 12 / 2002
Page 11 of 11
6
Technical data
Optical data, Sharp Max
Collimator:
achromat, f =200mm
Exit pupil:
50mm
Siemens star:
72 sectors, smallest grating constant approx. 4.4µm
Illumination:
green LEDs,
λ 570nm, adjustable brightness and illumination-ON period
Admissible testpiece data
Focal length:
5mm to 70mm
Ambient conditions
Temperature range:
-20°C to +40°C
Power supply
9V block battery, 6LR 61 type, alternatively 9V NiCd rechargeable battery
or external 12V DC / 100mA power source
Options
Lens flange for lenses from other manufacturers