beautypg.com

Louisville Tin and Stove 90N30A User Manual

Page 2

background image

Hourly BTU Input

30,000

50,000

62,000

75,000

Width and Length

14”x32”

22”x32”

24”x38”

26”x42”

Overall Height

29-1/4”

29-1/4”

29-7/8”

30-7/8”

Overall Grille Size

16”x34-

c”

24”x34”

26”x40”

28”x44”

Size of Floor Opening

14

3”x323” 222”x322” 242”x382” 262”x422”

Gas Pipe Size at Furnace

½”

½”

½”

½”

Vent Pipe Size

4”

4”

5”

5”

Floor to Center Line of Vent

22”

22”

22”

22”

SAFETY RULES

1.

WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN
CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. INSTALLATION AND SERVICE MUST
BE PERFORMED BY A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER. KEEP BURNER
AND CONTROL COMPARTMENT CLEAN. SEE INSTALLATION AND OPERATING INSTRUCTIONS
ACCOMPANYING APPLIANCE. DUE TO HIGH SURFACE TEMPERATURES KEEP CHILDREN, CLOTHING
AND FURNITURE AWAY.

CONTENTS:

Introduction............................................... 2
Specifications ............................................ 2
Safety Rules............................................... 2
Helpful Installation Information................. 3
Installation Requirements........................... 3
Furnace Location....................................... 4
Fresh Air for Combustion & Venting.......... 4
Cutting the Floor Opening.......................... 5
Setting the Floor Furnace...........................

5

Installing the Draft Hood............................ 6
Connecting the Vent....................................6
Gas Supply and Piping................................ 8

Checking the Gas Piping........................... 9
Thermostat Installation............................. 10
Lighting.................................................... 11
To Turn Off Gas....................................... 11
Adjusting the Pilot Flame..........................12
Orifice Charts........................................... 12
Adjusting the Main Burner........................ 12
Optional Operation....................................13
Maintenance..............................................14
Trouble Shooting.......................................15
Repair Parts...............................................16
Warranty....................................................18

MODEL NUMBER – NAT. GAS

90N30A

90N50A

90N65A

90N75A

INTRODUCTION

THIS IS A GAS-FIRED, GRAVITY VENTED FLOOR FURNACE THAT WILL OPERATE SAFELY
AND PROVIDE AN EFFICIENT SOURCE OF HEAT WHEN INSTALLED, OPERATED AND
MAINTAINED AS RECOMMENDED IN THESE INSTALLATION AND OPERATING
INSTRUCTIONS. READ THESE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING,
SERVICING, OR USING THE APPLIANCE. IF YOU DO NOT UNDERSTAND ANY PART OF
THESE INSTRUCTIONS, CONSULT LOCAL AUTHORITIES, OTHER QUALIFIED
INSTALLERS, SERVICE AGENCIES, THE GAS SUPPLIER OR THE MANUFACTURER.

FLOOR FURNACE SPECIFICATIONS

Your floor furnace and drafthood are packed together in one master carton. The carton containing the floor
furnace also contains the thermostat, thermostat wire, insulated staples, furnace key and lighter rod. The drafthood
is packed in its own carton within the master pack and contains screws and rope-like gasket material for attaching
and sealing the draft hood to the floor furnace. Check the model numbers on the two cartons to be sure they
match.

Page 2