beautypg.com

A.2 environmental requirements – Cabletron Systems FOMIM-32 User Manual

Page 29

background image

Appendix A: FOMIM Specifications

A-2

FOMIM User’s Guide

A.2

ENVIRONMENTAL REQUIREMENTS

Operating Temperature:

+5

°

to +40

°

C (41

°

to 104

°

F)

Non-operating Temperature:

-30

°

to +80

°

C (-22

°

to 176

°

F)

Operating Humidity:

5% to 95% (non-condensing)

Table A-2

Fiber Optic Interface (All Ports)

Parameter

Typical

Minimum

Maximum

Transmitter
Peak Wave
Length

1310 nm

1265 nm

1380 nm

Spectral Width

95 nm

125 nm

Rise Time

3.0 ns

2.7 ns

5.0 ns

Fall Time

2.5 ns

2.2 ns

5.0 ns

Duty Cycle

50.1%

49.6%

50.7%

Bit Error Rate

Better than 10

-10

NOTES

The transmitter power levels given above are Peak Power
Levels after optical overshoot. You must use a Peak Power
Meter to correctly compare the values given above to those
measured on any particular port.

If you are measuring power levels with an Average Power
Meter, add 3 dBm to the average power measurement to
compare the measured average power values to the values
listed above (i.e., -33.5 dBm average + 3 dB = -30.5 dBm peak).

This manual is related to the following products: