A.2 environmental requirements – Cabletron Systems FOMIM-32 User Manual
Page 29

Appendix A: FOMIM Specifications
A-2
FOMIM User’s Guide
A.2
ENVIRONMENTAL REQUIREMENTS
Operating Temperature:
+5
°
to +40
°
C (41
°
to 104
°
F)
Non-operating Temperature:
-30
°
to +80
°
C (-22
°
to 176
°
F)
Operating Humidity:
5% to 95% (non-condensing)
Table A-2
Fiber Optic Interface (All Ports)
Parameter
Typical
Minimum
Maximum
Transmitter
Peak Wave
Length
1310 nm
1265 nm
1380 nm
Spectral Width
95 nm
125 nm
Rise Time
3.0 ns
2.7 ns
5.0 ns
Fall Time
2.5 ns
2.2 ns
5.0 ns
Duty Cycle
50.1%
49.6%
50.7%
Bit Error Rate
Better than 10
-10
NOTES
The transmitter power levels given above are Peak Power
Levels after optical overshoot. You must use a Peak Power
Meter to correctly compare the values given above to those
measured on any particular port.
If you are measuring power levels with an Average Power
Meter, add 3 dBm to the average power measurement to
compare the measured average power values to the values
listed above (i.e., -33.5 dBm average + 3 dB = -30.5 dBm peak).