background image

TECHNICAL DATA

Gas connection

Rp

1

/

2

(

1

/

2

” BSP female)

Pressure test point

Front left hotplate injector

Gas rate adjustment

None

Aeration adjustment

None

Electrical connection

4mm

2

twin and earth

230/240V a.c. 50Hz.

24

HEAT
INPUT

G20 at 20mbar

G30 at 28-30mbar
G31 at 37mbar

BURNER

INJECTOR

2.2 / 2.4 kW

GRILL

1.8 / 2.0 kW

MAIN OVEN

1.7 / 1.9 kW

TOP OVEN

3.0 kW

HOTPLATE
Front left and rear right

116

2.0 kW

HOTPLATE
Front right and rear left

103

HEAT
INPUT

INJECTOR

3.0 kW (220g/h)

86

2.0 kW (145g/h)

70