Install Covers and Restart Water Heater
INSTALL COVERS
After installing your water softener, replace the covers.
Angle the covers so the main cover clips onto the back
first, then bring down in front and clip on the two (2) tabs
inside the rim of the salt hole and lower the salt cover
closed. See Fig. 23.
RESTART THE WATER HEATER
Turn on the gas (or electric) supply to the water heater
and light the pilot.
YOUR PLUMBING INSTALLATION AND ELECTRICAL
WORK ARE NOW COMPLETE.
Program The Timer
PROGRAM THE TIMER
1. When the transformer is plugged in, a model code and a
test number (example: J11) show in the face plate. This
will display for four (4) seconds. Then, 12:00 AM and
PRESENT TIME begin to flash.
NOTE: If “
-------- ”
shows in the display, press the UP or
DOWN button until either S 32, for Model 38356, or
S 33, for Model 39356, shows in the display Then,
press the SELECT button to set, and change to the
flashing PRESENT TIME display.
2. To check the model code, unplug the transformer at the
wall outlet and plug in again. If other than this code
shows, refer to the Troubleshooting Section.
SOUND “BEEPER”: A “beeper” sounds while pressing
buttons for timer setup. One beep signals a change in the
face plate display. Repeated beeps mean the timer will not
accept a change from the button you have pressed, telling
you to use another button. For example, while setting the
hardness the beeper sounds repeatedly when the display
reaches 1 using the DOWN button, or the highest hard
ness setting using the UP button.
Model 38356
Model 39356
FIG. 24
I
IC'ULI
PRESENT TIME
FIG. 25
Questions? Call The Kenmore Water Line 1-800-426-9345
17