CUT HAZARD
Failure to follow this caution may result in personal

injury.
Although special care has been taken to minimize sharp

edges in the construction of your unit, be extremely

careful when handling parts or reaching into the unit.

Wear appropriate protective clothing and gloves when

working on this unit.

CAUTION

!

PERFORMING ROUTINE

MAINTENANCE

1. The motors are factory lubricated. Lubricating the bearings

is not recommended.

2. The heat recovery core must be handled with care. To ensure

maximum efficiency of the plastic partitions wash core once
a year following the season of most intense use.

Allow the heat recovery core to soak for 3 hours in a solution
of warm water and mild soap. Rinse under a stream of warm

water. Hot water and strong detergent should NOT be used,
as it will damage the heat recovery core.

3. A dirty air filter will cause excessive strain on the blower

motor. The filters in your HRV are washable and should be
cleaned every 3 months. Use a vacuum cleaner to remove the

heaviest portion of accumulated dust, then wash in warm
water.

The Air Exchange Indicator light on the auto control will
indicate when filters should be cleaned. The light will flash
on and off until the door is opened to service the unit.

4. Regularly check the screen on the exterior intake hood and

clean as necessary.

5. Examine the condensate drain pan to ensure drains are

functioning properly. Gently clean tray with mild soapy
water. (See Fig. 3 and 4).

BEFORE YOU REQUEST

A SERVICE CALL

S

Check the main power disconnect switch. Verify that the
circuit breakers are ON or that fuses have not blown. If you
must reset breakers or replace fuses, do so only once. Contact

your servicing dealer for assistance if the breakers trip or the
fuses blow a second time.

S

Check for sufficient airflow. Check air filters for
accumulations of large particles. Check for blocked
exhaust--air grilles or ductwork. Keep grilles and duct work

open and unobstructed.

S

If the condensate fails to drain properly, check the grommet
and drain tube for obstructions. Make sure that the condensate

drain tube has a slight slope and is not kinked.

If your HRV still fails to operate properly, contact your servicing

dealer. Give him your model and serial number. With this informa-
tion, the dealer will be able to correct any problems.

Table 1—Recommended Humidity Settings

OUTSIDE TEMPERATURE

DOUBLE---PANE WINDOWS

TRIPLE---PANE WINDOWS

50° F

10° C

55 percent

65 percent

32° F

0° C

45 percent

55 percent

14° F

---10° C

35 percent

45 percent

---4° F

---20° C

30 percent

45 percent

---22° F

---30° C

25 percent

35 percent

STALE AIR
FROM BUILDING

FRESH AIR
TO BUILDING

FRESH AIR

FROM OUTSIDE

STALE AIR

TO OUTSIDE

A92382

Fig. 3 -- Vertical Application