Electrical requirements, Observe all local codes and ordinances, Electrical ground is required on this appliance – Kenmore 580.75080 User Manual
Page 4: Do not use an extension cord, Recommended grounding method, 115v, 230v, Warning
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
ELECTRICAL REQUIREMENTS
OBSERVE ALL LOCAL CODES AND
ORDINANCES.
DO NOT, UNDER ANY CIRCUMSTANCES,
REMOVE THE POWER SUPPLY CORD
GROUND PRONG.
ELECTRICAL GROUND IS REQUIRED ON
THIS APPLIANCE.
A 250-volt 60 Hz, AC only, 20A fused and
properly grounded electrical supply is required.
A time delay fuse or time delay circuit breaker
is recommended. Use a dedicated circuit,
serving only this appliance.
DO NOT USE AN EXTENSION CORD.
RECOMMENDED GROUNDING METHOD
For your personal safety, this appliance must
be grounded. This appliance has a power
supply cord with a 3-prong grounding plug. To
minimize possible shock hazard, the cord must
be plugged into a mating grounding type wall
receptacle and grounded in accordance with
the National Electrical Code (ANSI/NFPA 70)
latest edition and all local codes and
ordinances. If a mating wall receptacle is not
available, it is the personal responsibility and
obligation of the customer to have a properly
grounded 3-prong wall receptacle installed by a
qualified electrician.
115V~
o
230V-
Power cord may include a current interrupter
device. A test and reset button is provided on the
plug case. The device should be tested on a
periodic basis by first pressing the TEST button
and then the
rese
T button. If the TEST button
does not trip or if the RESET button will not stay
engaged, discontinue use of the air conditioner and
contact a qualified service technician.
NOTE:
The shape may be different according to its model.
Use Wall Receptacle
Power Supply
^
\ Standard 125V,
f 1 1 \ 3-wire grounding
V
0
y receptacle rated
15A, 125VAC
Use 15 AMP. time
delay fuse or 15 AMP.
circuit breaker.
Standard 250V,
(^
3-wire
grounding
\ A / receptacle rated
Vyfr-V 15A, 250VAC
^
'X Standard 250V,
/ 1 3-wire grounding
1
_ / receptacle rated
20A, 250V AC
Use 20 AMP. time
delay fuse or 20 AMP.
circuit breaker.
A
warning
S
m
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire, or electrical shock.
-4-